Analyses of the Temperature Field of a Piezoelectric Micro Actuator in the Endoscopic Biopsy Channel
Open Access
- 23 October 2019
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 9 (21) , 4499
Abstract
Micro actuators have been used to realize the arrival of digestive tract lesions for the local targeted application of drugs in endoscopes. However, there still exists a key safety issue that casts a shadow over the practical and safe implementation of actuators in the human body, namely an overheated environment caused by actuators’ operation. Herein, with the aim of solving the temperature rising problem of a piezoelectric micro actuator operating in an endoscopic biopsy channel (OLYMPUS, Tokyo, Japan), a thermal finite element method (FEM) based on COMSOL Multiphysics software is proposed. The temperature distribution and its rising curves are obtained by the FEM method. Both the simulated and experimental maximum temperatures are larger than the safety value (e.g., 42 °C for human tissues) when the driving voltage of the actuator is 200 Vpp, which proves that the overheating problem really exists in the actuator. Furthermore, the results show that the calculated temperature rising curves correspond to the experimental results, proving the effectiveness of this FEM method. Therefore, we introduce a temperature control method through optimizing the duty ratio of the actuator. In comparison with a 100% duty ratio operation condition, it is found that a 60% duty ratio with a driving voltage of 200 Vpp can more effectively prevent the temperature rising issue in the first 3 min, as revealed by the corresponding temperatures of 44.4 and 41.4 °C, respectively. When the duty ratio is adjusted to 30% or less, the temperature rise of the actuator can be significantly reduced to only 36.6 °C, which is close to the initial temperature (36.4 °C). Meanwhile, the speed of the actuator can be well-maintained at a certain level, demonstrating its great applicability for safe operation in the human body.Keywords
Funding Information
- National Natural Science Foundation of China (51875280)
- Outstanding Youth Science Foundation of Jiangsu Province (BK20180067)
This publication has 31 references indexed in Scilit:
- Polyimide/substituted polyaniline–copolymer–nanoclay composite thin films with high damping abilitiesJournal of Applied Polymer Science, 2012
- Bio-effects and safety of low-intensity, low-frequency ultrasonic exposureProgress in Biophysics and Molecular Biology, 2012
- Multidisciplinary treatment with chemotherapy, targeted drug, and high-intensity focused ultrasound in advanced pancreatic carcinomaMedical Oncology, 2011
- Ultra-compact, zero-power magnetic latching piezoelectric inchworm motor with integrated position sensorSensors and Actuators A: Physical, 2010
- Active gastrointestinal bleeding: Use of hemostatic forceps beyond endoscopic submucosal dissectionWorld Journal of Gastroenterology, 2010
- Evaluation of hemostasis with soft coagulation using endoscopic hemostatic forceps in comparison with metallic hemoclips for bleeding gastric ulcers: a prospective, randomized trialJournal of Gastroenterology, 2009
- Improving Conventional or Low Dose Metronomic Chemotherapy with Targeted Antiangiogenic DrugsCancer Research and Treatment, 2007
- Endoscopic hemostatic devices: May 2001Gastrointestinal Endoscopy, 2001
- Clinical, histologic, and electron microscopy study of skin exposed to low‐frequency ultrasoundThe Anatomical Record, 2001
- Crack propagation in a glass particle-filled epoxy resinJournal of Materials Science, 1984