Free‐breathing multislice native myocardial T1 mapping using the slice‐interleaved T1 (STONE) sequence
Open Access
- 1 August 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (1) , 115-124
Abstract
Purpose: To develop a novel pulse sequence for free‐breathing, multislice, native myocardial T1 mapping.Methods: The slice‐interleaved T1 (STONE) sequence consists of multiple sets of single‐shot images of different slices, acquired after a single nonselective inversion pulse. Each slice is only selectively excited once after each inversion pulse to allow sampling of the unperturbed longitudinal magnetization in the adjacent slices. For respiratory motion, a prospective slice‐tracking respiratory navigator is used to decrease through‐plane motion followed by a retrospective image registration to reduce in‐plane motion. STONE T1 maps were calculated using both a two‐parameter and three‐parameter fit model. The accuracy and precision of the STONE sequence for different T1, T2, and inversion pulse efficiency were studied using numerical simulations and phantom experiments. T1 maps from 14 subjects were acquired with the STONE sequence and T1s were compared to the MOdified Look‐Locker Inversion recovery sequence (MOLLI).Results: In numerical simulations and phantom experiments, the STONE sequence using a two‐parameter fit model yields more accurate T1 times compared to MOLLI, with similar high precision. The three‐parameter fit model further improves the accuracy, but with a reduced precision. The native myocardial T1 times were higher in the STONE sequence using two‐ or three‐parameter fit compared to MOLLI. The standard deviation of the T1 times was lower in the STONE T1 maps with a two‐parameter fit compared with MOLLI or a three‐parameter fit.Conclusion: The STONE sequence allows accurate and precise quantification of native myocardial T1 times with the additional benefit of covering the entire ventricle. Magn Reson Med 74:115–124, 2015.Keywords
Funding Information
- NIH (R01EB008743-01A2)
- Samsung Electronics
This publication has 32 references indexed in Scilit:
- T 1 measurements in the human myocardium: The effects of magnetization transfer on the SASHA and MOLLI sequencesMagnetic Resonance in Medicine, 2013
- Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scannersJournal of Cardiovascular Magnetic Resonance, 2013
- Influence of Off-resonance in myocardial T1-mapping using SSFP based MOLLI methodJournal of Cardiovascular Magnetic Resonance, 2013
- T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precisionJournal of Cardiovascular Magnetic Resonance, 2013
- T2-dependent errors in MOLLI T1 values: simulations, phantoms, and in-vivo studiesJournal of Cardiovascular Magnetic Resonance, 2012
- Diffuse myocardial fibrosis in hypertrophic cardiomyopathy can be identified by cardiovascular magnetic resonance, and is associated with left ventricular diastolic dysfunctionJournal of Cardiovascular Magnetic Resonance, 2012
- T1 mapping of the myocardium: intra-individual assessment of post-contrast T1 time evolution and extracellular volume fraction at 3T for Gd-DTPA and Gd-BOPTAJournal of Cardiovascular Magnetic Resonance, 2012
- Assessment of Myocardial Fibrosis With Cardiovascular Magnetic ResonanceJACC, 2011
- Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathholdJournal of Cardiovascular Magnetic Resonance, 2010
- Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heartMagnetic Resonance in Medicine, 2004