Controlling the biodegradation rate of magnesium using biomimetic apatite coating

Authors:

Abstract
Magnesium is light, biocompatible and has similar mechanical properties to natural bone, so it has the potential to be used as a biodegradable material for orthopedic applications. However, pure magnesium severely corrodes in a physiological environment, which may result in fracture prior to substantial tissue healing. Hydroxyapatite (HA) is the main composition of natural bone. It has excellent bioactivity and osteoconductivity. In this study, HA coating with two different thicknesses was applied onto the surface of pure magnesium substrates using a biomimetic technique. The corrosion rate of the surface‐treated substrates was tested. It was found that both types of coatings substantially slowed down the corrosion of the substrate, and the dual coating was more effective than the single coating in hindering the degradation of the substrate. Thus, the corrosion rate of magnesium implants can be closely tailored by adjusting apatite coating thickness and thereby monitoring the release of magnesium ions into the body. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009

This publication has 24 references indexed in Scilit: