Microcomputed Tomography Calibration Using Polymers and Minerals for Enamel Mineral Content Quantitation
Open Access
- 1 March 2019
- journal article
- research article
- Published by S. Karger AG in Medical Principles and Practice
- Vol. 28 (3) , 247-255
Abstract
Objective: The aim of this paper was to develop calibration standards (CSs) that are readily available for clinical researchers for the quantitation of enamel mineral content. Method:Polyethylene terephthalate (PET), acetal, polyphenylene sulfide (PPS), selenite, Egyptian alabaster, aragonite, and fluorite were fashioned into discs, and their densities were measured and stacked for microcomputed tomography examination. Frame averaging, flat-field correction, pre-filtration, and beam-hardening correction were applied. CSs were checked for homogeneity. The linear relationship between the mean greyscale value (GSV) of each disc and its physically calculated density was explored, and reproducibility was tested. A calibration function was established and then validated using a bovine enamel disc and sound enamel of extracted human premolar teeth. Results: Measured densities were PET (ρ = 1.38 g/cm3), acetal (ρ = 1.41 g/cm3), PPS (ρ = 1.64 g/cm3), selenite (ρ = 2.24 g/cm3), Egyptian alabaster (ρ = 2.7 g/cm3), aragonite (ρ = 2.72 g/cm3), and fluorite (ρ = 3.11 g/cm3). Examination of the profile sections of CSs confirmed the uniformity of GSVs with minimal beam-hardening effect. A squared Pearson correlation coefficient of R2 = 0.994 was determined between the mean GSV of each CS and its calculated density and was reproduced at different settings with R2 >0.99. A linear regression equation of density (y) versus GSV (x) was established using the least squares regression equation method. The estimated density of the bovine enamel disc (2.48 g/cm3) showed high accuracy when compared to the physically measured value (2.45 g/cm3). The relative error was 1.2%. Densities of sound enamel in the extracted human premolar teeth were 2.6–3.1 g/cm3. Conclusions: This is a simple, valid, and reproducible method to quantitate enamel mineral content. This simple, yet accurate system could be used to expand knowledge in the field of enamel caries research.Keywords
This publication has 30 references indexed in Scilit:
- A Micro-Computed Tomography Study of the Root Canal Morphology of Mandibular First Premolars in an Emirati PopulationMedical Principles and Practice, 2016
- A comparative study of new and current methods for dental micro-CT image denoisingDentomaxillofacial Radiology, 2016
- Sodium fluoride mouthrinse used twice daily increased incipient caries lesion remineralization in an in situ modelJournal of Dentistry, 2014
- Application of Polychromatic µCT for Mineral Density DeterminationJournal of Dental Research, 2010
- Mineral Concentration of Natural Human Teeth by a Commercial Micro-CTDental Materials Journal, 2006
- X-ray microtomographic study of mineral concentration distribution in deciduous enamelArchives of Oral Biology, 2004
- Synchrotron X-Ray Microtomographic Investigation of Mineral Concentrations at Micrometre Scale in Sound and Carious EnamelCaries Research, 2004
- Quantitative analysis of bone mineral content by x-ray microtomographyPhysiological Measurement, 2003
- X‐ray microtomographic study of mineral distribution in enamel of mandibular rat incisorsJournal of Anatomy, 2000
- Correction for beam hardening artefacts in computerised tomography.1998