Denoising of Contrast-Enhanced Ultrasound Cine Sequences Based on a Multiplicative Model
- 27 February 2015
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 62 (8) , 1969-1980
Abstract
Background: Speckle noise is an inherent characteristic of dynamic contrast-enhanced ultrasound (DCEUS) movies and ultrasound images in general. Speckle noise considerably reduces the quality of these images and limits their clinical use. Currently, temporal compounding and maximum intensity persistence (MIP) are among the most widely accepted processing methods enabling the visualization of vasculature using DCEUS. Goal: A different approach has been used in this study, in order to improve the noise removal, while enabling the investigation of CEUS dynamics. Methods: A multiplicative model for the formation of DCEUS speckled images is adopted and the log-transformed cines are processed. A preprocessing step was performed, locally removing low value outliers. Due to the fast-changing spatial distribution of microbubbles inside the vasculature, the noise in consecutive DCEUS frames is independent, facilitating its removal by temporal denoising. Noise reduction is efficiently achieved by wavelet denoising, in which the signal's wavelet coefficients are thresholded and small-value noise-related coefficients are discarded. The main advantage of using wavelet denoising in the present context is its ability to estimate ultrasound contrast agents' (UCA) concentration over time adaptively, without assuming a model or predefining the signal's degree of smoothness. The performance of wavelet denoising was compared against MIP, temporal compounding, and Log-normal model fitting. Results: Phantom experiments showed improved SNR, using wavelet denoising over a wide range of UCA concentrations (MicroMarker, 0.001-1%). In the in vivo tests, improved noise removal was achieved, reflected by a significantly lower coefficient of variation in homogeneous vascular regions ($p <; 0.01$ ).Keywords
Funding Information
- Canadian Institutes of Health Research
- Terry Fox Foundation, the Ontario Research Fund, and VisualSonics Inc.
This publication has 24 references indexed in Scilit:
- Assessment and Monitoring Tumor Vascularity With Contrast-Enhanced Ultrasound Maximum Intensity Persistence ImagingInvestigative Radiology, 2011
- Investigation of the Relationship of Nonlinear Backscattered Ultrasound Intensity with Microbubble Concentration at Low MIUltrasound in Medicine & Biology, 2010
- Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineeringPhysics in Medicine & Biology, 2009
- Contrast Enhanced Ultrasound Flash Replenishment Method for Directed Prostate BiopsiesJournal of Urology, 2007
- Robust estimation of ultrasound pulses using outlier-resistant de-noisingIEEE Transactions on Medical Imaging, 2003
- A novel multiscale nonlinear thresholding method for ultrasonic speckle suppressingIEEE Transactions on Medical Imaging, 1999
- Speckle reduction and contrast enhancement of echocardiograms via multiscale nonlinear processingIEEE Transactions on Medical Imaging, 1998
- Adapting to Unknown Smoothness via Wavelet ShrinkageJournal of the American Statistical Association, 1995
- De-noising by soft-thresholdingIEEE Transactions on Information Theory, 1995
- A model for non-Rayleigh sea echoIEEE Transactions on Antennas and Propagation, 1976