Radiation imaging of a highly contaminated filter train inside Fukushima Daiichi Nuclear Power Station unit 2 using an integrated Radiation Imaging System based on a Compton camera
Open Access
- 22 January 2023
- journal article
- research article
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 60 (8) , 1013-1026
Abstract
The Fukushima Daiichi Nuclear Power Station (FDNPS) suffered a meltdown in the aftermath of the large tsunami caused by the Great East Japan Earthquake that occurred on 11 March 2011. A massive amount of radioactive substance was spread over a wide area both inside and outside the FDNPS site. In this study, we present an approach for visualizing a radioactive hotspot on a standby gas-treatment system filter train, a highly contaminated piece of equipment in the air-conditioning room of the Unit 2 reactor building of FDNPS, using radiation imaging based on a Compton camera. In addition to fixed-point measurements using only the Compton camera, data acquisition while moving using an integrated Radiation Imaging System (iRIS), which combines a Compton camera with a simultaneous localization and mapping device and a survey meter, enabled the three-dimensional visualization of the hotspot location on the filter train. In addition, we visualized the hotspot and quantitatively evaluated its radioactivity. Notably, the visualized hotspot location and estimated radioactivity value are consistent with the accident investigation report of the FDNPS. Finally, the extent to which the radioactivity increased the ambient dose equivalent rate in the surrounding environment was explored. Graphical abstractKeywords
Funding Information
- TEPCO
This publication has 13 references indexed in Scilit:
- Real-Time Free-Moving Active Coded Mask 3D Gamma-Ray ImagingIEEE Transactions on Nuclear Science, 2019
- Radiation imaging using a compact Compton camera mounted on a crawler robot inside reactor buildings of Fukushima Daiichi Nuclear Power StationJournal of Nuclear Science and Technology, 2019
- Development of an all-sky gamma-ray Compton camera based on scintillators for high-dose environmentsJournal of Nuclear Science and Technology, 2018
- Radiation imaging using a compact Compton camera inside the Fukushima Daiichi Nuclear Power Station buildingJournal of Nuclear Science and Technology, 2018
- Development of compact Compton camera for 3D image reconstruction of radioactive contaminationJournal of Instrumentation, 2017
- Handheld real-time volumetric 3-D gamma-ray imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2017
- Performance and field tests of a handheld Compton camera using 3-D position-sensitive scintillators coupled to multi-pixel photon counter arraysJournal of Instrumentation, 2014
- “Stereo Compton cameras” for the 3-D localization of radioisotopesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Development of a gamma camera to image radiation fieldsProgress in Nuclear Science and Technology, 2014
- Handy Compton camera using 3D position-sensitive scintillators coupled with large-area monolithic MPPC arraysNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013