Optimized Camera-Based Patient Positioning in CT
- 2 August 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 58 (2) , 126-130
Abstract
Objective: The aim of this study was to evaluate whether a 3-dimensional (3D) camera can outperform highly trained technicians in precision of patient positioning and whether this transforms into a reduction in patient exposure. Materials and Methods: In a single-center study, 3118 patients underwent computer tomography (CT) scans of the chest and/or abdomen on a latest generation single-source CT scanner supported with an automated patient positioning system by 3D camera. One thousand five hundred fifty-seven patients were positioned laser-guided by a highly trained radiographer (camera off) and 1561 patients with 3D camera (camera on) guidance. Radiation parameters such as effective dose, organ doses, CT dose index, and dose length product were analyzed and compared. Isocenter accuracy and table height were evaluated between the 2 groups. Results: Isocenter positioning was significantly improved with the 3D camera (P < 0.001) as compared with visual laser-guided positioning. Absolute table height differed significantly (P < 0.001), being higher with camera positioning (165.6 ± 16.2 mm) as compared with laser-guided positioning (170.0 ± 20.4 mm). Radiation exposure decreased using the 3D camera as indicated by dose length product (321.1 ± 266.6 mGy·cm; camera off: 342.0 ± 280.7 mGy·cm; P = 0.033), effective dose (3.3 ± 2.7 mSv; camera off: 3.5 ± 2.9; P = 0.053), and CT dose index (6.4 ± 4.3 mGy; camera off: 6.8 ± 4.6 mGy; P = 0.011). Exposure of radiation-sensitive organs such as colon (P = 0.015) and red bone marrow (P = 0.049) were also lower using the camera. Conclusions: The introduction of a 3D camera improves patient positioning in the isocenter of the scanner, which results in a lower and also better balanced dose reduction for the patients.Keywords
This publication has 29 references indexed in Scilit:
- Effect of Patient Centering on Patient Dose and Image Noise in Chest CTAmerican Journal of Roentgenology, 2014
- Effect of vertical positioning on organ dose, image noise and contrast in pediatric chest CT—phantom studyPediatric Radiology, 2013
- Impact of miscentering on patient dose and image noise in x-ray CT imaging: Phantom and clinical studiesPhysica Medica, 2012
- Automated Computed Tomography Dose-Saving Algorithm to Protect Radiosensitive TissuesInvestigative Radiology, 2012
- Efficient use of automatic exposure control systems in computed tomography requires correct patient positioningActa Radiologica, 2009
- The effect of angular and longitudinal tube current modulations on the estimation of organ and effective doses in x‐ray computed tomographyMedical Physics, 2009
- Misoperation of CT Automatic Tube Current Modulation Systems with Inappropriate Patient Centering: Phantom StudiesAmerican Journal of Roentgenology, 2009
- The influence of patient centering on CT dose and image noiseMedical Physics, 2007
- Use of an Automatic Exposure Control Mechanism for Dose Optimization in Multi–Detector Row CT Examinations: Clinical EvaluationRadiology, 2005
- Techniques and Applications of Automatic Tube Current Modulation for CTRadiology, 2004