Evaluation of ciliary body morphology and position of the implantable collamer lens in low-vault eyes using ultrasound biomicroscopy
- 1 November 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (11) , 1133-1139
Abstract
Purpose: To investigate the ciliary body anatomy and position of the implantable collamer lens (ICL) in low-vault eyes and analyze factors related to insufficient vault. Setting: Zhongshan Ophthalmic Center, Guangzhou, China. Design: Retrospective case–control observational study. Methods: In this study, 73 eyes of 73 patients with an insufficient vault (P < .005). The ciliary process length (CPL) and maximum ciliary body thickness (CBTmax) were significantly smaller, and the trabecular–ciliary angle (TCA), iris–ciliary angle (ICA), and ciliary sulcus width (CSW) were significantly greater in the low-vault eyes (all P < .005). The low-vault group had more ICL haptics below the ciliary process, and TCA, ICA, CPL, CBTmax, CSW, and haptic position were related to the postoperative vault (all P < .05). CPL, AL, and LT were identified as predictors of a low vault. Conclusions: Malposition of ICL haptics behind the ciliary process is a risk factor for low vault. A shorter CPL, thicker LT, and shorter AL are significant risk factors for the postoperative low vault.Keywords
This publication has 26 references indexed in Scilit:
- Posterior chamber phakic intraocular lens sizing based on iris pigment layer measurements by anterior segment optical coherence tomographyJournal of Cataract & Refractive Surgery, 2015
- Observing implantable collamer lens dislocation by panoramic ultrasound biomicroscopyEye, 2015
- Comparison of Postoperative Vault Height Predictability Using White-to-White or Sulcus Diameter–based Sizing for the Visian Implantable Collamer LensJournal of Refractive Surgery, 2013
- Optimization of an Implantable Collamer Lens Sizing Method Using High-Frequency Ultrasound BiomicroscopyAmerican Journal of Ophthalmology, 2012
- Improving accuracy of phakic intraocular lens sizing using high-frequency ultrasound biomicroscopyJournal of Cataract & Refractive Surgery, 2011
- Posterior Chamber Phakic Implantable Collamer Lens: Changes in Vault During 1 YearJournal of Refractive Surgery, 2010
- Phakic Intraocular Lens Implantation for the Correction of MyopiaA Report by the American Academy of OphthalmologyOphthalmology, 2009
- Toric Implantable Collamer Lens for Moderate to High Myopic AstigmatismOphthalmology, 2007
- United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopiaOphthalmology, 2004
- U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopiaOphthalmology, 2003