Intravenous Contrast Material Administration at 16–Detector Row Helical CT Coronary Angiography: Test Bolus versus Bolus-tracking Technique
Authors:
- Filippo CademartiriFCFilippo Cademartiri
- Koen NiemanKNKoen Nieman
- Aad van der LugtALAad van der Lugt
- Rolf H. RaaijmakersRRRolf H. Raaijmakers
- Nico MolletNMNico Mollet
- Peter M. T. PattynamaPPPeter M. T. Pattynama
- Pim J. de FeyterPFPim J. de Feyter
- Gabriel P. KrestinGKGabriel P. Krestin
- 1 December 2004
- journal article
- clinical trial
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 233 (3) , 817-823
Abstract
To compare test bolus and bolus-tracking techniques for intravenous contrast material administration at 16-detector row computed tomographic (CT) coronary angiography. This study had institutional review board approval, and patients gave informed consent. Thirty-eight patients (mean age, 60 years; three women) were randomized into two groups according to bolus timing technique: group 1 (20-mL test bolus with 100-mL main bolus) and group 2 (bolus tracking with 100-mL main bolus). All patients underwent electrocardiography-gated 16-detector row CT coronary angiography with 12 detectors (collimation, 0.75 mm; rotation time, 420 msec). In group 1, test bolus peak attenuation was used as a delay, while in group 2, a +100-HU threshold in ascending aorta triggered angiographic acquisition, with an additional 4-second delay for patient instruction. Attenuation was measured in the longitudinal direction throughout the examination in three main vessels: ascending aorta (region of interest [ROI] 1), descending aorta (ROI 2), and main pulmonary artery (ROI 3). Mean attenuation and slope of bolus geometry curve were calculated in each patient and ROI. Attenuation at origin of coronary arteries was measured. Student t test was used to compare results. Mean scan delay was 6 seconds longer in group 2 (P < .05). Average attenuation values were 306.6 HU +/- 44.0 (standard deviation) and 328.2 HU +/- 58.6 (P > .05) in ROI 1, 291.6 HU +/- 45.1 and 326.4 HU +/- 62.6 (P > .05) in ROI 2, and 354.7 HU +/- 78.0 and 305.3 HU +/- 71.4 (P < .05) in ROI 3 for groups 1 and 2, respectively. Average slope values were 5.8 and -0.8 (P < .05) in ROI 1, 7.7 and 0.7 (P < .05) in ROI 2, and -1.0 and -13.3 (P < .05) in ROI 3 for groups 1 and 2, respectively. Average attenuation values in left main, left anterior descending, and left circumflex arteries were higher in group 2 (P < .05); there were no differences (P > .05) between groups in right coronary artery. Bolus-tracking yields more homogeneous enhancement than does the test bolus technique.Keywords
This publication has 21 references indexed in Scilit:
- Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar ReconstructionCirculation, 2003
- Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed TomographyCirculation, 2002
- New Technical Developments in Multislice CT, Part 2: Sub-Millimeter 16-Slice Scanning and Increased Gantry Rotation Speed for Cardiac ImagingRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- New technical developments in multislice CT - Part 1: Approaching isotropic resolution withsub-millimeter 16-slice scanning -RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Parameters Affecting Bolus Geometry in CTA: A ReviewJournal of Computer Assisted Tomography, 2002
- Darstellung der Herzkranzgefäße im CT mittels neuer 16-Zeilen-Technologie und reduzierter Rotationszeit: Erste ErfahrungenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenosesThe American Journal of Cardiology, 2001
- Coronary angiography with multi-slice computed tomographyThe Lancet, 2001
- Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CTCirculation, 2000
- Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate--pharmacokinetic analysis and experimental porcine model.Radiology, 1998