The semi-quantitative distribution of T4 and T6 surface antigens on human Langerhans cells

Authors:

Abstract
We have used indirect immunogold electron microscopy to compare the respective density of cell membrane determinants revealed by OKT6 and OKT4 monoclonal antibodies on normal human Langerhans cells (LC): 12.9 +/- 3.5 gold granules were noted per cell section on OKT4-positive LC whereas 236.8 +/- 23.5 granules were counted per cell section on OKT6-reactive cells. These results confirm that human LC react with OKT4 antibody and they demonstrate a marked quantitative difference on LC surface between the antigenic determinants recognized by OKT6 and OKT4 antibodies.