Limits for Resolving Isobaric Tandem Mass Tag Reporter Ions Using Phase-Constrained Spectrum Deconvolution
Open Access
- 16 September 2018
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 17 (11) , 4008-4016
Abstract
A popular method for peptide quantification relies on isobaric labeling such as tandem mass tags (TMT), which enables multiplexed proteome analyses. Quantification is achieved by reporter ions generated by fragmentation in a tandem mass spectrometer. However, with higher degrees of multiplexing, the smaller mass differences between the reporter ions increase the mass resolving power requirements. This contrasts with faster peptide sequencing capabilities enabled by lowered mass resolution on Orbitrap instruments. It is therefore important to determine the mass resolution limits for highly multiplexed quantification when maximizing proteome depth. Here, we defined the lower boundaries for resolving TMT reporter ions with 0.0063 Da mass differences using an ultra-high-field Orbitrap mass spectrometer. We found the optimal method depends on the relative ratio between closely spaced reporter ions and that 64 ms transient acquisition time provided sufficient resolving power for separating TMT reporter ions with absolute ratio changes up to 16-fold. Furthermore, a 32 ms transient processed with phase-constrained spectrum deconvolution provides >50% more identifications with >99% quantified but with a slight loss in quantification precision and accuracy. These findings should guide decisions on what Orbitrap resolution settings to use in future proteomics experiments, relying on isobaric TMT reporter ion quantification.Keywords
All Related Versions
Funding Information
- Kræftens Bekæmpelse (R90-A5844 KBVU)
- Novo Nordisk Fonden (NNF14CC0001)
- Horizon 2020 Framework Programme (NNF17SA0027704)
- Horizon 2020 (686547)
This publication has 27 references indexed in Scilit:
- A Sulfoxide‐Based Isobaric Labelling Reagent for Accurate Quantitative Mass SpectrometryAngewandte Chemie International Edition, 2018
- Enhanced Fourier transform for Orbitrap mass spectrometryInternational Journal of Mass Spectrometry, 2014
- Orbitrap Mass SpectrometryAnalytical Chemistry, 2013
- Accurate Multiplexed Proteomics at the MS2 Level Using the Complement Reporter Ion ClusterAnalytical Chemistry, 2012
- Increasing the Multiplexing Capacity of TMTs Using Reporter Ion Isotopologues with Isobaric MassesAnalytical Chemistry, 2012
- High-Resolution Enabled TMT 8-plexingAnalytical Chemistry, 2012
- Mass Spectrometry-based Proteomics Using Q Exactive, a High-performance Benchtop Quadrupole Orbitrap Mass SpectrometerMolecular & Cellular Proteomics, 2011
- The Orbitrap: a new mass spectrometerJournal of Mass Spectrometry, 2005
- Multiplexed Protein Quantitation in Saccharomyces cerevisiae Using Amine-reactive Isobaric Tagging ReagentsMolecular & Cellular Proteomics, 2004
- Tandem Mass Tags: A Novel Quantification Strategy for Comparative Analysis of Complex Protein Mixtures by MS/MSAnalytical Chemistry, 2003