Understanding the Application of Mechanical Dyssynchrony in Patients with Heart Failure Considered for CRT
Open Access
- 17 February 2024
- journal article
- review article
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (2) , 64
Abstract
Over the past two decades of CRT use, the failure rate has remained around 30–35%, despite several updates in the guidelines based on the understanding from multiple trials. This review article summarizes the role of mechanical dyssynchrony in the selection of heart failure patients for cardiac resynchronization therapy. Understanding the application of mechanical dyssynchrony has also evolved during these past two decades. There is no role of lone mechanical dyssynchrony in the patient selection for CRT. However, mechanical dyssynchrony can complement the electrocardiogram and clinical criteria and improve patient selection by reducing the failure rate. An oversimplified approach to mechanical dyssynchrony assessment, such as just estimating time-to-peak delays between segments, should not be used. Instead, methods that can identify the underlying pathophysiology of HF and are representative of a substrate to CRT should be applied.Keywords
This publication has 56 references indexed in Scilit:
- Echocardiography-Guided Left Ventricular Lead Placement for Cardiac Resynchronization TherapyCirculation: Heart Failure, 2013
- A novel clinical method for quantification of regional left ventricular pressure–strain loop area: a non-invasive index of myocardial workEuropean Heart Journal, 2012
- The relationship between ventricular electrical delay and left ventricular remodelling with cardiac resynchronization therapyEuropean Heart Journal, 2011
- Left Ventricular Lead Position and Clinical Outcome in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) TrialCirculation, 2011
- Relationship of Echocardiographic Dyssynchrony to Long-Term Survival After Cardiac Resynchronization TherapyCirculation, 2010
- Noninvasive Imaging in Cardiac Resynchronization Therapy—Part 1: Selection of PatientsPacing and Clinical Electrophysiology, 2008
- A Prospective Comparison of AV Delay Programming Methods for Hemodynamic Optimization during Cardiac Resynchronization TherapyJournal of Cardiovascular Electrophysiology, 2007
- Prospective comparison of echocardiographic atrioventricular delay optimization methods for cardiac resynchronization therapyHeart Rhythm, 2006
- Determination of the optimal atrioventricular delay in DDD pacing. Comparison between echo and peak endocardial acceleration measurementsEP Europace, 1999
- Endocardial activation of left bundle branch block.Circulation, 1984