Overview on the progress of the conceptual studies of a gamma ray spectrometer instrument for DEMO
Authors:
- 1 August 2022
- journal article
- conference paper
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (08) , C08020
Abstract
The future DEMO tokamak will be equipped with a suite of diagnostics which will operate as sensors to monitor and control the position and operation parameters of DT plasmas. Among the suite of sensors, an integrated neutron and gamma-ray diagnostic system is also studied to verify its capability and performance in detecting possible DEMO plasma position variations and contribute to the feedback system in maintaining DEMO DT plasma in stable conditions. This work describes the progress of the conceptual study of the gamma-ray diagnostic for DEMO reactor performed during the first Work-Package contract 2015–2020. The reaction of interest for this Gamma-Ray Spectrometer Instrument (GRSI) consists of D(T, γ)5He with the emission of 16.63 MeV γ rays. Due to DEMO tokamak design constraints, the gamma and neutron diagnostics are integrated, both featuring multi-line of sight (camera type), viewing DEMO plasma radially with vertical (12) and horizontal (13) viewing lines to diagnose the γ and neutron emission from the DT plasma poloidal section. The GRSI design is based on the investigation of the reaction cross sections, on the calculations performed with GENESIS and MCNP simulation codes and on the physics and geometry constrains of the integrated instrument. GRSI features long collimators which diameters are constrained by the neutron flux at the neutron detectors of the Radial Neutron Camera (RNC) system placed in front, which are key to control DEMO DT plasma position. For these reasons, only few GRSI parameters can be independently selected to optimize its performance. Among these, the choice of the collimator diameters at the back side of the neutron detector box up to the GRSI detector, the use of LiH neutron attenuators in front of the GRSI detectors, the GRSI detector material and shielding. The GRSI detector is based on commercial LaBr3(Ce) inorganic scintillating crystal coupled with a photomultiplier tube or a silicon photomultiplier. They are designed to operate at high count rate although GRSI geometry constraints severely impact on this feature. The GRSI can also provide an independent assessment of DEMO DT fusion power and T burning.Keywords
This publication has 14 references indexed in Scilit:
- Conceptual design of the radial gamma ray spectrometers system forαparticle and runaway electron measurements at ITERNuclear Fusion, 2017
- Gamma-ray emission spectrum from thermonuclear fusion reactions without intrinsic broadeningNuclear Fusion, 2015
- DEMO diagnostics and burn controlFusion Engineering and Design, 2015
- On the core deuterium–tritium fuel ratio and temperature measurements in DEMONuclear Fusion, 2015
- Simulation of 16 O (n, p) 16 N reaction rate and nitrogen-16 inventory in a high performance light water reactor with one pass coreApplied Radiation and Isotopes, 2014
- Determination of the deuterium-tritium branching ratio based on inertial confinement fusion implosionsPhysical Review C, 2012
- First Gamma-Ray Measurements of Fusion Alpha Particles in JET Trace Tritium ExperimentsPhysical Review Letters, 2004
- Energy levels of light nuclei A = 16–17Nuclear Physics A, 1993
- O16(n, d)N15gs and O16(n, p)N16 reactions at 14.4 MeVPhysics Letters, 1964
- Cross Sections for theReaction from 12 to 18 MevPhysical Review B, 1954