Hip reconstruction using a customized intercalary prosthesis with the rhino horn-designed uncemented stem for ultrashort proximal femur segments following tumor resection: a combined biomechanical and clinical study
Open Access
- 8 September 2022
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-14
Abstract
Background: Hip-preserved reconstruction for patients with ultrashort proximal femur segments following extensive femoral diaphyseal tumor resection is a formidable undertaking. A customized intercalary prosthesis with a rhino horn-designed uncemented stem was developed for the reconstruction of these extensive skeletal defects. Methods: This study was designed to analyze and compare the differences in the biomechanical behavior between the normal femur and the femur with diaphyseal defects reconstructed by an intercalary prosthesis with different stems. The biomechanical behavior under physiological loading conditions is analyzed using the healthy femur as the reference. Five three-dimensional finite element models (healthy, customized intercalary prosthesis with four different stems implemented, respectively) were developed, together with a clinical follow-up of 12 patients who underwent intercalary femoral replacement. Results: The biomechanical results showed that normal-like stress and displacement distribution patterns were observed in the remaining proximal femur segments after reconstructions with the rhino horn-designed uncemented stems, compared with the straight stem. Stem A showed better biomechanical performance, whereas the fixation system with Stem B was relatively unstable. The clinical results were consistent with the FEA results. After a mean follow-up period of 32.33 ± 9.12 months, osteointegration and satisfactory clinical outcomes were observed in all patients. Aseptic loosening (asymptomatic) occurred in one patient reconstructed by Stem B; there were no other postoperative complications in the remaining 11 patients. Conclusion: The rhino horn-designed uncemented stem is outstanding in precise shape matching and osseointegration. This novel prosthesis design may be beneficial in decreasing the risk of mechanical failure and aseptic loosening, especially when Stem A is used. Therefore, the customized intercalary prosthesis with this rhino horn-designed uncemented stem might be a reasonable alternative for the reconstruction of SSPF following extensive tumor resection.Keywords
Funding Information
- the Fundamental Research Funds for the Central Universities (2021SCU12010)
- Chengdu science and technology project (2017-CY02- 00032-GX)
- 8122 Project, Qingdao Research Institute of Sichuan University (20GZ30301)
This publication has 35 references indexed in Scilit:
- A Dual-center Review of Compressive Osseointegration for Fixation of Massive Endoprosthetics: 2- to 9-year FollowupClinical Orthopaedics and Related Research, 2014
- Distal Femur Allograft Prosthetic Composite Reconstruction for Short Proximal Femur Segments following Tumor ResectionAdvances in Orthopedics, 2013
- Early follow-up of a custom non-fluted diaphyseal press-fit tumour prosthesisInternational Orthopaedics, 2013
- Stress and stability comparison between different systems for high tibial osteotomiesBMC Musculoskeletal Disorders, 2013
- Femoral diaphyseal endoprosthetic reconstruction after segmental resection of primary bone tumoursThe Journal of Bone and Joint Surgery. British volume, 2010
- Evaluation of bone plate with low-stiffness material in terms of stress distributionJournal of Biomechanics, 2008
- Uncemented Tumor Endoprostheses at the KneeClinical Orthopaedics and Related Research, 2005
- Determination of muscle loading at the hip joint for use in pre-clinical testingJournal of Biomechanics, 2005
- The effect of muscle loading on the simulation of bone remodelling in the proximal femurJournal of Biomechanics, 2005
- LETTERS TO THE EDITORClinical Orthopaedics and Related Research, 1983