Effect of poly-hexamethylene biguanide hydrochloride (PHMB) treated non-sterile medical gloves upon the transmission of Streptococcus pyogenes, carbapenem-resistant E. coli, MRSA and Klebsiella pneumoniae from contact surfaces
Open Access
- 17 August 2017
- journal article
- research article
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 17 (1) , 1-8
Abstract
Reduction of accidental contamination of the near-patient environment has potential to reduce acquisition of healthcare-associated infection(s). Although medical gloves should be removed when soiled or touching the environment, compliance is variable. The use of antimicrobial-impregnated medical gloves could reduce the horizontal-transfer of bacterial contamination between surfaces. Determine the activity of antimicrobial-impregnated gloves against common hospital pathogens: Streptococcus pyogenes, carbapenem-resistant E.coli (CREC), MRSA and ESBL-producing Klebsiella pneumoniae. Fingerpads (~1cm2) of PHMB-treated and untreated gloves were inoculated with 10 μL (~104 colony-forming-units [cfu]) of test-bacteria prepared in heavy-soiling (0.5%BSA), blood or distilled-water (no-soiling) and sampled after 0.25, 1, 10 or 15 min contact-time. Donor surfaces (~1cm2 computer-keys) contaminated with wet/dry inoculum were touched with the fingerpad of treated/untreated gloves and subsequently pressed onto recipient (uncontaminated) computer-keys. Approximately 4.50log10cfu of all bacteria persisted after 15 min on untreated gloves regardless of soil-type. In the absence of soiling, PHMB-treated gloves reduced surface-contamination by ~4.5log10cfu (>99.99%) within 10 min of contact-time but only ~2.5log10 (>99.9%) and ~1.0log10 reduction respectively when heavy-soiling or blood was present. Gloves became highly-contaminated (~4.52log10–4.91log10cfu) when handling recently-contaminated computer-keys. Untreated gloves contaminated “recipient” surfaces (~4.5log10cfu) while PHMB-treated gloves transferred fewer bacteria (2.4–3.6log10cfu). When surface contamination was dry, PHMB gloves transferred fewer bacteria (0.3–0.6log10cfu) to “recipient” surfaces than untreated gloves (1.0–1.9log10; P < 0.05). Antimicrobial-impregnated gloves may be useful in preventing dissemination of organisms in the near-patient environment during routine care. However they are not a substitute for appropriate hand-hygiene procedures.Keywords
Funding Information
- NIHR University College London Hospitals Biomedical Research Centre
This publication has 22 references indexed in Scilit:
- In-vitro experimental evaluation of skin-to-surface recovery of four bacterial species by antibacterial and non-antibacterial medical examination glovesAntimicrobial Resistance & Infection Control, 2013
- Hand hygiene after touching a patient's surroundings: the opportunities most commonly missedJournal of Hospital Infection, 2013
- Concentration of bacteria passing through puncture holes in surgical glovesAmerican Journal of Infection Control, 2010
- Role of hand hygiene in healthcare-associated infection preventionJournal of Hospital Infection, 2009
- Laboratory and in-use assessment of methicillin-resistant Staphylococcus aureus contamination of ergonomic computer keyboards for ward useAmerican Journal of Infection Control, 2008
- Risk of Hand or Glove Contamination After Contact With Patients Colonized With Vancomycin-ResistantEnterococcusor the Colonized Patients' EnvironmentInfection Control & Hospital Epidemiology, 2008
- Misuse of gloves: the foundation for poor compliance with hand hygiene and potential for microbial transmission?Journal of Hospital Infection, 2004
- Dynamics of Bacterial Hand Contamination During Routine Neonatal CareInfection Control & Hospital Epidemiology, 2004
- Inoculum Size Influences Bacterial CrossContamination betweenSurfacesApplied and Environmental Microbiology, 2003
- Rapid Inactivation of Infectious Pathogens by Chlorhexidine-Coated GlovesInfection Control & Hospital Epidemiology, 1992