Intracranial pressure (ICP) monitoring is important in managing neurosurgical, neurological, and ophthalmological patients with open-angle glaucoma. Non-invasive two-depth transcranial Doppler (TCD) technique is used in a novel method for ICP snapshot measurement that has been previously investigated prospectively, and the results showed clinically acceptable accuracy and precision. The aim of this study was to investigate possibility of using the ophthalmic artery (OA) as a pressure sensor for continuous ICP monitoring. First, numerical modeling was done to investigate the possibility, and then a pilot clinical study was conducted to compare two-depth TCD-based non-invasive ICP monitoring data with readings from an invasive Codman ICP microsensor from patients with severe traumatic brain injury. The numerical modeling showed that the systematic error of non-invasive ICP monitoring was < 1.0 mmHg after eliminating the intraorbital and blood pressure gradient. In a clinical study, a total of 1928 paired data points were collected, and the extreme data points of measured differences between invasive and non-invasive ICP were − 3.94 and 4.68 mmHg (95% CI − 2.55 to 2.72). The total mean and SD were 0.086 ± 1.34 mmHg, and the correlation coefficient was 0.94. The results show that the OA can be used as a linear natural pressure sensor and that it could potentially be possible to monitor the ICP for up to 1 h without recalibration.Keywords
Funding Information
- Lietuvos Mokslo Taryba (MIP-087/2015)
This publication has 42 references indexed in Scilit:
- Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A ReviewCritical Care Research and Practice, 2012
- Clinical assessment of noninvasive intracranial pressure absolute value measurement methodNeurology, 2012
- 3D constitutive modeling of the biaxial mechanical response of intact and layer-dissected human carotid arteriesJournal of the Mechanical Behavior of Biomedical Materials, 2012
- Cerebrospinal Fluid Pressure in GlaucomaOphthalmology, 2010
- Intracranial Pressure in Primary Open Angle Glaucoma, Normal Tension Glaucoma, and Ocular Hypertension: A Case–Control StudyInvestigative Ophthalmology & Visual Science, 2008
- Cerebrospinal Fluid Pressure Is Decreased in Primary Open-angle GlaucomaOphthalmology, 2008
- Computational modeling of arterial wall growthBiomechanics and Modeling in Mechanobiology, 2006
- Orbital vascular anatomyEye, 2006
- Direct orbital manometry in patients with thyroid-associated orbitopathyOphthalmology, 1999
- Numerical solution of the quasilinear poisson equation in a nonuniform triangle meshJournal of Computational Physics, 1966