Error indicators for fully automatic extraction of heat-transfer macromodels for MEMS
Authors:
- 17 December 2004
- journal article
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 15 (3) , 430-440
Abstract
In this paper, we present three heuristic error indicators for the iterative model order reduction of electro-thermal MEMS models via the Arnoldi algorithm. Such error indi- cators help a designer to choose an optimal order of the reduced model, required to achieve a desired accuracy, and hence allow a completely automatic extraction of heat- transfer macromodels for MEMS. We first suggest a convergence criterion between two successive reduced models of order and . We further propose to use a solution of the Lyapunov equations for reduced-order systems in each iteration, and alternatively to employ sequential model order reduction, which is based on consecutively applying Arnoldi and control-theory methods.Keywords
This publication has 22 references indexed in Scilit:
- Fabrication and testing of an integrated thermal flow sensor employing thermal isolation by a porous silicon membrane over an air cavityJournal of Micromechanics and Microengineering, 2004
- An all-dielectric tunable optical filter based on the thermo-optic effectJournal of Optics A: Pure and Applied Optics, 2004
- Extraction of heat-transfer macromodels for MEMS devicesJournal of Micromechanics and Microengineering, 2004
- A novel single chip thin film metal oxide arraySensors and Actuators B: Chemical, 2003
- An arnoldi based thermal network reduction method for electro-thermal analysisIEEE Transactions on Components and Packaging Technologies, 2003
- Creating compact models of complex electronic systems: an overview and suggested use of existing model reduction and experimental system identification toolsIEEE Transactions on Components and Packaging Technologies, 2003
- Review: Automatic Model Reduction for Transient Simulation of MEMS‐based DevicesSensors Update, 2002
- Time dependent temperature fields calculated using eigenfunctions and eigenvalues of the heat conduction equationMicroelectronics Journal, 2001
- A robust micro conveyer realized by arrayed polyimide joint actuators1Journal of Micromechanics and Microengineering, 2000
- Thermal dynamics and the time constant domainIEEE Transactions on Components and Packaging Technologies, 2000