Test cells for use with anti‐IgG sub‐typing antisera in the antiglobulin test
Authors:
- V. I. RawlinsonVRV. I. Rawlinson
- F. StrattonFSF. Stratton
- A. H. MerryAMA. H. Merry
- 2 January 1985
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 25 (1) , 27-29
Abstract
The preparation of test cells coated with specific IgG of known subclass is described. Such cells are required in the standardization of IgG subtyping reagents. At present, these test cells usually are prepared by coating cells with IgG myeloma paraproteins. These paraproteins may not be generally available and an alterantive method is presented using more readily obtainable materials. Quantification of cell-bound IgG showed that the subclass did not affect the sensitivity of the antiglobulin test when using broad-spectrum anti-IgG and that the test cells produced had an optimal IgG coating. Reactions with subclass-specific antisera were however, considerably weaker than those obtained with broad-spectrum anti-IgG. A modified spin-layering technique for use with subclass-specific antisera is described.Keywords
This publication has 5 references indexed in Scilit:
- Standardization of IgG subclass antiserums for use with sensitized red cellsTransfusion, 1983
- A quantitative antiglobulin test for IgG for use in blood transfusion serologyClinical and Laboratory Haematology, 1982
- Chloroquine dissociation of antigen‐antibody complexesTransfusion, 1982
- Preparation of test cells for the antiglobulin testJournal of Clinical Pathology, 1974
- The IgG Subclasses of Red Cell Antibodies and Relationship to Monocyte BindingBlood, 1972