Schiff base functionalized silica gel for simultaneous separation and preconcentration of Cu(II), Ni(II), and Cd(II) in pharmaceuticals and water samples
Open Access
- 1 January 2022
- journal article
- research article
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 46 (2) , 459-474
Abstract
A method for separation and preconcentration of Cu(II), Ni(II), and Cd(II) using N-N'-bis(5-methoxsalicylidene)-2-hydroxy-1,3-propanediamine modified silica gel was improved for aqueous samples and pharmaceuticals. Determination of the analytes was achieved by inductively coupled plasma optic emission spectrometry. The experimental conditions including pH value, sample volume, eluent type and volume, sorbent mass, sample, and eluent flow rates were optimized with univariate and multivariate optimization tools. The relative standard deviations of the method were 2.9% for Cu(II), 3.0% for Ni(II), and 3.3% for Cd(II) with recovery values between 98.8 ± 3.2-101.5 ± 3.0%. The limits of detection were found to be 62.4, 39.5, and 28.2 ng L-1 for Cu(II), Ni(II), and Cd(II), respectively. The accuracy of the suggested procedure was tested with the certified reference material (Certipur ICP multi-element standard solution IV) and addition-recovery experiments. The method was successfully applied to eye drop, anesthetic, serum, tap water, mineral water, and spring water samples.Keywords
This publication has 7 references indexed in Scilit:
- Simultaneous Spectrometric Determination of Cu(II), Co(II), and Ni(II) in Pharmaceutical and Environmental Samples with XAD-4/DMMDTC Solid-Phase Extraction SystemBiological Trace Element Research, 2019
- Preconcentration of Cu(II), Co(II), and Ni(II) using an Optimized Enrichment Procedure: Useful and Alternative Methodology for Flame Atomic Absorption SpectrometryApplied Spectroscopy, 2016
- Separation and preconcentration system based on ultrasonic probe-assisted ionic liquid dispersive liquid–liquid microextraction for determination trace amount of chromium(VI) by electrothermal atomic absorption spectrometryTalanta, 2010
- Utilization of membrane filtration for preconcentration and determination of Cu(II) and Pb(II) in food, water and geological samples by atomic absorption spectrometryFood and Chemical Toxicology, 2010
- Preconcentration of some trace elements via using multiwalled carbon nanotubes as solid phase extraction adsorbentJournal of Hazardous Materials, 2009
- A preconcentration system for determination of copper and nickel in water and food samples employing flame atomic absorption spectrometryJournal of Hazardous Materials, 2009
- On-line liquid–liquid extraction system using a new phase separator for flame atomic absorption spectrometric determination of ultra-trace cadmium in natural watersTalanta, 2004