Performance Test and Evaluation of Multilevel Fresnel Zone Plate with Three-Step Profile Fabricated with Electron-Beam Lithography
- 26 January 2012
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 51 (2R) , 022502
Abstract
A multilevel Fresnel zone plate (FZP) designed as an approximation of a kinoform profile has been developed. The FZP is made by electron-beam lithography and reactive ion etching. The zone structure consists of three levels made from tantalum with a total thickness of 4 µm. The half pitch of the outermost zone structure is 0.6 µm. The theoretical efficiency of the 1st-order diffraction is 0.49 at an X-ray energy of 9.85 keV. A performance test is carried out at the beamline 20XU of SPring-8. The focused beam width is measured to be 0.6 µm. The measured efficiency of the 1st-order diffraction is 0.39 at 9.85 keV. Although the measured efficiency is less than the theoretical value, it is superior to the efficiency of an optimized tantalum binary FZP. The diffraction efficiencies of the 0th, -1st, and ±2nd orders are also measured. Using the measured data, the structure of the fabricated zone is evaluated.Keywords
This publication has 18 references indexed in Scilit:
- Fabrication and Performance Test of Fresnel Zone Plate with 35 nm Outermost Zone Width in Hard X-Ray RegionX-Ray Optics and Instrumentation, 2010
- X-ray Holographic Microscopy by Double-Prism InterferometerJapanese Journal of Applied Physics, 2010
- Full-field hard x-ray microscopy below 30 nm: a challenging nanofabrication achievementNanotechnology, 2008
- 30 nm resolution x-ray imaging at 8keV using third order diffraction of a zone plate lens objective in a transmission microscopeApplied Physics Letters, 2006
- Development of micro-tomography system with Fresnel zone plate optics at SPring-82006
- Performance Test of Fresnel Zone Plate with 50 nm Outermost Zone Width in Hard X-ray RegionJapanese Journal of Applied Physics, 2005
- Resolution Limit of Refractive Lens and Fresnel Lens in X-Ray RegionJapanese Journal of Applied Physics, 2004
- High-sensitive imaging with scanning transmission hard X-ray microscopeJournal de Physique IV, 2003
- X-ray multilevel zone plate fabrication by means of electron-beam lithography: Toward high-efficiency performancesJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 1999
- High-efficiency multilevel zone plates for keV X-raysNature, 1999