Computed tomographic‐dacryocystography (CT‐DCG) of the normal canine nasolacrimal drainage system with three‐dimensional reconstruction
Authors:
- 26 April 2011
- journal article
- Published by Wiley in Veterinary Ophthalmology
- Vol. 14 (3) , 174-179
Abstract
The aims of the study were (1) to quantify the influence of selected imaging parameters on the image quality (slice thickness, mAs, and beam orientation) defining optimal conditions for scan protocols and (2) to evaluate the benefits of the 3D reconstruction techniques for visualization of NDS structures in dogs. CT‐DCG was performed bilaterally in 32 heads of dogs. CT transverse images were obtained using a combination of two slice thickness values (0.8 mm and 2 mm) and two mAs values (50 mAs and 300 mAs). Two beam projection orientations were also tested: transverse plane (perpendicular to the hard palate) and oblique to the hard palate. Three‐dimensional images were obtained using Volume Rendering (VR). Transverse beam projection proved to be superior for the assessment of the inferior and superior lacrimal canaliculi and lacrimal sac. In this study, there was no statistical difference regarding mAs values (50 mAs and 300 mAs) and slice thickness values (0.8 mm and 2 mm). Three‐dimensional images were helpful for the assessment of topographic relationship between nasolacrimal structures and cranial landmarks.Keywords
This publication has 12 references indexed in Scilit:
- Qualitative and quantitative tear film abnormalities in dogsCiência Rural, 2008
- Helical computed tomographic dacryocystography and its role in the diagnosis and management of lacrimal drainage system blocks and medial canthal massesIndian Journal Of Ophthalmology, 2008
- Volume Rendering versus Maximum Intensity Projection in CT Angiography: What Works Best, When, and WhyRadioGraphics, 2006
- Introduction to the Language of Three-dimensional Imaging with Multidetector CTRadioGraphics, 2005
- Helical Computed Tomographic Dacryocystography With Three-Dimensional ReconstructionOphthalmic Plastic & Reconstructive Surgery, 2002
- Three-dimensional Volume Rendering of Spiral CT Data: Theory and MethodRadioGraphics, 1999
- Topical contrast-enhanced CT and MR dacryocystography: imaging the lacrimal drainage apparatus of healthy volunteers.American Journal of Roentgenology, 1998
- Skeletal 3-D CT: advantages of volume rendering over surface renderingSkeletal Radiology, 1996
- Computed tomographic dacryocystographyBritish Journal of Radiology, 1993
- Radiology in Ophthalmic DiagnosisVeterinary Clinics of North America: Small Animal Practice, 1980