Covalently-Bound Heparin Makes Collagen Thromboresistant
Authors:
- 1 March 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 24 (3) , 613-617
Abstract
Objective— Blood compatibility of artificial surfaces depends on their immunogenic and thrombogenic properties. Collagen’s weak antigenicity makes it an attractive candidate for stent coatings or fabrication of vascular grafts. However, the thrombogenic nature of collagen limits its application. We examined whether heparinization can make collagen more thromboresistant. Methods and Results— Collagen was heparinized by crosslinking collagen with extensively periodate oxidized heparin and/or by covalently bonding of mildly periodate oxidized heparin. Both ways of heparinization have no effect on platelet adhesion and could not abolish induction of platelet procoagulant activity. However, thrombin generation was completely prevented under static and flow conditions. The functionality of immobilized heparin was confirmed by specific uptake of antithrombin, 13.5±4.7 pmol/cm 2 and 1.95±0.21 pmol/cm 2 for mildly and heavily periodated heparin, respectively. Conclusions— These results indicate that immobilization of heparin on collagen, even as a crosslinker, is a very effective way to prevent surface thrombus formation. These data encourage the application of heparinized collagen as stent-graft material in animal and eventually human studies.Keywords
This publication has 27 references indexed in Scilit:
- Platelet-collagen interaction: is GPVI the central receptor?Blood, 2003
- Thrombogenicity of polysaccharide-coated surfacesBiomaterials, 2003
- von Willebrand factor stimulates thrombin-induced exposure of procoagulant phospholipids on the surface of fibrin-adherent plateletsJournal of Thrombosis and Haemostasis, 2003
- Inflammation and Restenosis in the Stent EraArteriosclerosis, Thrombosis, and Vascular Biology, 2002
- Endovascular Stents and Stent-Grafts: Is Heparin Coating Desirable?CardioVascular and Interventional Radiology, 2000
- Bovine Type I Collagen as an Endovascular Stent-Graft Material: Biocompatibility Study in RabbitsRadiology, 2000
- Receptors and signalling mechanisms in the procoagulant response of plateletsPlatelets, 2000
- Activation of blood coagulation at heparin-coated surfacesJournal of Biomedical Materials Research, 1997
- Dacron-covered stent-grafts for the percutaneous treatment of carotid aneurysms: effectiveness and biocompatibility--experimental study in swine.Radiology, 1996
- Polymeric stenting in the porcine coronary artery model: Differential outcome of exogenous fibrin sleeves versus polyurethane-coated stentsJACC, 1994