New Prosthetic Restorative Features of the Ankylos Implant System
Author:
- 1 June 2004
- journal article
- review article
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 30 (3) , 178-188
Abstract
Problem: All oral implant systems rely on the abutment part of the implant to provide stability for the dental prosthetic. The Ankylos implant offers precisely machined, tapered-cone abutment (Morse taper) connection. This tapered abutment connection provides high resistance to bending and rotational torque during clinical function, which significantly reduces the possibilities of screw fracture or loosening. Purpose: This report describes the design and mechanical construction characteristics of the Ankylos implant system that make it possible for the system to provide final restorations that are natural looking, esthetically acceptable, durable, and cost effective. Methods: Review of the clinical literature. Results: The clinical results of single-tooth crowns borne on Ankylos implants in the lateral tooth region are excellent after a minimum of 5 years in function (mean = 6.3 years) compared with the high prosthetic complication rate with other systems. Abutment loosening occurred in only 1.3%...Keywords
This publication has 11 references indexed in Scilit:
- Persistent Acute Inflammation at the Implant-Abutment InterfaceJournal of Dental Research, 2003
- Nobel Perfect™ Esthetic Scalloped Implant: Rationale for a New DesignClinical Implant Dentistry and Related Research, 2003
- Influence of the Size of the Microgap on Crestal Bone Levels in Non‐Submerged Dental Implants: A Radiographic Study in the Canine MandibleJournal of Periodontology, 2002
- Biologic Width around one‐ and two‐piece titanium implantsClinical Oral Implants Research, 2001
- The Effect of Inter‐Implant Distance on the Height of Inter‐Implant Bone CrestJournal of Periodontology, 2000
- REPLACING POSTERIOR TEETH WITH FREESTANDING IMPLANTS: FOUR-YEAR PROSTHODONTIC RESULTS OF A PROSPECTIVE STUDYThe Journal of the American Dental Association, 1998
- Reduction of Implant Loading With Therapeutic BiomechanicsImplant Dentistry, 1998
- Titanium implants and lateral forces. An experimental study with sheep.Clinical Oral Implants Research, 1997
- Biologic Width Around Titanium Implants. A Histometric Analysis of the Implanto‐Gingival Junction Around Unloaded and Loaded Nonsubmerged Implants in the Canine MandibleJournal of Periodontology, 1997
- A comparative study of one implant versus two replacing a single molarImplant Dentistry, 1997