A Triple‐Stack Column Procedure for Rapid Separation of Cu and Zn from Geological Samples
- 6 April 2020
- journal article
- research article
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 44 (3) , 407-420
Abstract
We present a new procedure for the separation and purification of Cu and Zn from geological samples. Our procedure employed a single pass, triple‐stack column set‐up. The first column, filled with TRU resin (TrisKem International), quantitatively removed Fe and Ti from sample matrices. A second column, filled with pre‐filter resin (TrisKem International), removed organic compounds. Finally, a third column, filled with anion exchange resin (AG1‐X8, 200–400 mesh, Bio‐Rad), was used to separate Cu and Zn from the remaining matrix. Our procedure required about 50% less acid volume than previously reported methods for Cu and Zn separation, thereby minimising analytical blanks and column running times. Copper and Zn stable isotope ratios were determined by a Thermo Neptune Plus MC‐ICP‐MS using Zn and Cu external normalisation, respectively, in addition to sample‐standard bracketing to correct for instrumental mass bias. We explore the inter‐calibration of Cu and Zn isotope fractionation coefficients during analysis by measuring mixed Cu–Zn solutions with enhanced mass bias variation generated by varying sample gas flow rates. Our results demonstrate that this procedure is useful when variation in instrumental mass bias throughout analytical sequences is insufficient to inter‐calibrate Cu and Zn fractionation coefficients.Keywords
Funding Information
- Natural Environment Research Council (NE/M0003/1, NE/M010848/1)
- Leverhulme Trust (RG95456)
This publication has 34 references indexed in Scilit:
- Inter-calibration of a proposed new primary reference standard AA-ETH Zn for zinc isotopic analysisJournal of Analytical Atomic Spectrometry, 2016
- Measurement of zinc stable isotope ratios in biogeochemical matrices by double-spike MC-ICPMS and determination of the isotope ratio pool available for plants from soilAnalytical and Bioanalytical Chemistry, 2010
- Copper isotope fractionation in sedimentary copper mineralization (Timna Valley, Israel)Chemical Geology, 2007
- Separation of copper, iron, and zinc from complex aqueous solutions for isotopic measurementChemical Geology, 2007
- Chemical Separation and Isotopic Variations of Cu and Zn From Five Geological Reference MaterialsGeostandards and Geoanalytical Research, 2006
- The determination of the isotopic composition of Cu and Zn in seawaterChemical Geology, 2006
- Sources of mass bias and isotope ratio variation in multi-collector ICP-MS: optimization of instrumental parameters based on experimental observationsJournal of Analytical Atomic Spectrometry, 2004
- Mass discrimination correction in multiple-collector plasma source mass spectrometry: an example using Cu and Zn isotopesJournal of Analytical Atomic Spectrometry, 2004
- Complexation of metal ions in brines: application of electronic spectroscopy in the study of the Cu(II)-LiCl-H 2 O system between 25 and 90°CGeochimica et Cosmochimica Acta, 2001
- A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopesInternational Journal of Mass Spectrometry, 1998