Background: An implant prosthesis aims to ensure the best possible rehabilitation of function and esthetics following tooth loss. Template-guided insertion is used to achieve an optimal position of the implant with regard to prosthetic restorability, bone availability, and condition of the surrounding soft tissues. The accuracy of template-guided implant placement is subject to various influencing factors. The clinically achievable accuracy depending on the macro design of the implant body was investigated in this prospective clinical study. Material and methods: In this prospective clinical study, 20 implants were placed in 20 patients. The implant had a pronounced conical outer geometry (Conelog ProgressiveLine, Camlog Wimsheim, Germany). Data from a study using an implant with a distinct cylindrical outer geometry were used as a comparison group (Conelog ScrewLine, Camlog, Wimsheim, Germany). The clinically achieved implant position was compared with the planned position. Results: The evaluation of the two-dimensional deviations in direction resulted in the following mean values (standard deviation) at the shoulder: 0.42 mm (0.33) in the buccolingual direction, 0.27 mm (0.25) in the mesiodistal direction, and 0.68 mm (0.55) in the apicocoronal direction. The mean angular deviation was 4.1° (2.3). The three-dimensional (3D) deviation was 0.94 mm (0.53) at the shoulder and 1.36 mm (0.62) at the apex of the implant. Significant differences between implants with different macro designs were found in the apicocoronal direction. In connection to this, a significant 3D deviation was found at the implant shoulder. Conclusions: Significant differences in height were found between the groups. The study had shown that the macro design of an implant has no influence on accuracy in all other directions. Overall, the implants showed a high level of accuracy and a low variation in values. The values were in the range determined by the template-guided insertion system in numerous other investigations. This provides good predictability of prosthetic rehabilitation. Trial registration: German Register for Clinical Studies (DRKS-ID: DRKS000018939). Date of registration: November 11, 2019.Keywords
Funding Information
- Oral Reconstruction Foundation, Basel, CH (OR41305-part2)
This publication has 40 references indexed in Scilit:
- Retrospective study to determine the accuracy of template-guided implant placement using a novel nonradiologic evaluation methodOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2016
- An Accuracy Study of Computer‐Planned Implant Placement in the Augmented Maxilla Using Mucosa‐Supported Surgical TemplatesClinical Implant Dentistry and Related Research, 2014
- Depth and lateral deviations in guided implant surgery: an RCT comparing guided surgery with mental navigation or the use of a pilot‐drill templateClinical Oral Implants Research, 2014
- A randomized clinical trial comparing guided implant surgery (bone‐ or mucosa‐supported) with mental navigation or the use of a pilot‐drill templateJournal of Clinical Periodontology, 2014
- How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide?International Journal of Oral and Maxillofacial Surgery, 2014
- Technical Accuracy of Printed Surgical Templates for Guided Implant Surgery with the coDiagnostiXTM SoftwareClinical Implant Dentistry and Related Research, 2013
- Accuracy of three different types of stereolithographic surgical guide in implant placement: An in vitro studyThe Journal of Prosthetic Dentistry, 2012
- Factors influencing transfer accuracy of cone beam CT‐derived template‐based implant placementClinical Oral Implants Research, 2011
- Evaluation of the difference in accuracy between implant placement by virtual planning data and surgical guide templates versus the conventional free-hand method – a combined in vivo – in vitro technique using cone-beam CT (Part II)Journal of Cranio-Maxillofacial Surgery, 2010