Correlation of clinical outcomes with bremsstrahlung and Y-90 PET/CT imaging findings following Y-90 radiosynoviorthesis: a prospective study
Open Access
- 31 May 2016
- journal article
- research article
- Published by Springer Nature in EJNMMI Research
- Vol. 6 (1) , 45
Abstract
It is unclear how to predict which patients will respond to Y-90 radiosynoviorthesis. The aim of this study is to correlate clinical outcomes following Y-90 radiosynoviorthesis with bremsstrahlung and Y-90 PET/CT imaging findings. Fifty-one joints underwent bremsstrahlung planar and Y-90 PET/CT imaging following Y-90 radiosynoviorthesis. The Y-90 distribution pattern on bremsstrahlung planar imaging was classified as diffuse or non-diffuse and compared with the intra or extra-articular location of activity on Y-90 PET/CT. Treatment response was assessed by patients and clinicians at 6 months. In patients who underwent bremsstrahlung SPECT, side-by-side comparison with PET was performed with image quality/resolution scored using a five-point-scale. Bremsstrahlung planar images were classified as diffuse in 33/51 (65 %) and non-diffuse in 18/51 (35 %) scans. There was no association between treatment response and the bremsstrahlung planar imaging pattern. PET/CT confirmed an intra-articular location in all 33/33 (100 %) diffuse scans and an extra-articular location in 3/18 (17 %) non-diffuse scans. Of the three joints with extra-articular activity, none had any treatment response. Excluding these three joints, there remained no association between the bremsstrahlung planar imaging pattern and treatment response. Of the 42 joints imaged with SPECT, PET image quality/resolution was classified as superior in 40 (95 %). In one patient with extra-articular activity on PET/CT, SPECT/CT was unable to definitively localise the activity to the intra or extra-articular space. The distribution pattern on bremsstrahlung planar imaging did not correlate with clinical outcome following Y-90 radiosynoviorthesis in our study population. However, in patients with non-diffuse planar imaging patterns, Y-90 PET/CT should be considered to exclude extra-articular activity with PET providing superior image quality compared to SPECT.Keywords
This publication has 14 references indexed in Scilit:
- Yttrium-90 distribution following radiosynoviorthesis of the knee joint in rheumatoid arthritis patients: a SPECT/CT studyAnnals of Nuclear Medicine, 2014
- Efficacy of yttrium-90 synovectomy across a spectrum of arthropathies in an era of improved disease modifying drugs and treatment protocolsInternational Journal of Rheumatic Diseases, 2013
- Comparison of positron emission tomography/CT and bremsstrahlung imaging following Y-90 radiation synovectomyJournal of Medical Imaging and Radiation Oncology, 2013
- PET/CT imaging of 90Y radiation synovectomyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2012
- Radiation synovectomy with (90)Yttrium, (186)Rhenium and (169)Erbium: a systematic literature review with meta-analyses.2009
- The intra-articular distribution of 90yttrium does not influence the clinical outcome of radiation synovectomy of the kneeAnnals of the Rheumatic Diseases, 2007
- Is radiation synovectomy for arthritis of the knee more effective than intraarticular treatment with glucocorticoids? Results of an eighteen‐month, randomized, double‐blind, placebo‐controlled, crossover trialArthritis & Rheumatism, 2005
- Correlation between radiation dose, synovial thickness, and efficacy of radiosynoviorthesis.1999
- Samarium-153-particulate hydroxyapatite radiation synovectomy: biodistribution data for chronic knee synovitis.1995
- Characteristics of radio-isotopes for intra-articular therapy.Annals of the Rheumatic Diseases, 1973