Ultrasound‐guided serratus anterior plane block combined with the two‐incision technique for subcutaneous ICD implantation
- 1 March 2018
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (5) , 517-523
Abstract
Background: The standard technique for implanting a subcutaneous implantable cardioverter defibrillator (S‐ICD) requires three incisions and the pocket of the device is created in the subcutaneous tissue of the left lateral thoracic wall. However, a two‐incision technique may be adopted, in which the cranial parasternal region is avoided and the device is positioned more deeply, completely under the latissimus dorsi muscle. This can also be combined with ultrasound‐guided serratus anterior plane block (US‐SAPB) for intraoperative anesthesia and perioperative analgesia. We describe our preliminary experience of US‐SAPB combined with the two‐incision intermuscular technique.Methods: We performed US‐SAPB 40 minutes before starting the procedure, while the patient was in the supine position. The devices were implanted under the latissimus dorsi muscle. All patients were followed‐up after hospital discharge.Results: Twelve patients (male 50%, 53 ± 16 years, body mass index 23 ± 4) underwent the S‐ICD implantation with the combined technique. The mean procedure duration was 47 ± 11 minutes. The procedure was successful and a shock energy of 65 J was successful in converting the induced ventricular fibrillation in all patients. The US‐SAPB was successful in 92% of cases and only one patient required convertion into general anesthesia due to pain during the procedure. In the postoperative period, patients did not report major discomfort and analgesics were not required. During a median follow‐up of 12 months, no complications were reported.Conclusions: Serratus anterior plane block combined with the intermuscular and two‐incision technique proved to be safe and effective during the S‐ICD implantation procedure.Keywords
This publication has 19 references indexed in Scilit:
- Substernal lead implantation: a novel option to manage DFT failure in S-ICD patientsClinical Research in Cardiology, 2014
- Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter DefibrillatorCirculation, 2013
- Serratus plane block: a novel ultrasound‐guided thoracic wall nerve blockAnaesthesia, 2013
- Two-incision technique for implantation of the subcutaneous implantable cardioverter-defibrillatorHeart Rhythm, 2013
- Local Anesthetics: Review of Pharmacological ConsiderationsAnesthesia Progress, 2012
- Evaluation of Early Complications Related to De Novo Cardioverter Defibrillator ImplantationJACC, 2010
- The pectoral fascia: Anatomical and histological studyJournal of Bodywork and Movement Therapies, 2009
- A cadaveric study of the serratus anterior muscle and the long thoracic nerveJournal of Shoulder and Elbow Surgery, 2008
- The Frequency and Incremental Cost of Major Complications Among Medicare Beneficiaries Receiving Implantable Cardioverter-DefibrillatorsJACC, 2006
- Implantable Cardioverter-DefibrillatorsJAMA, 2006