Diffusion-Weighted MRI for Verification of Electroporation-Based Treatments
Open Access
- 6 March 2011
- journal article
- research article
- Published by Springer Nature in The Journal of Membrane Biology
- Vol. 240 (3) , 131-138
Abstract
Clinical electroporation (EP) is a rapidly advancing treatment modality that uses electric pulses to introduce drugs or genes into, e.g., cancer cells. The indication of successful EP is an instant plasma membrane permeabilization in the treated tissue. A noninvasive means of monitoring such a tissue reaction represents a great clinical benefit since, in case of target miss, retreatment can be performed immediately. We propose diffusion-weighted magnetic resonance imaging (DW-MRI) as a method to monitor EP tissue, using the concept of the apparent diffusion coefficient (ADC). We hypothesize that the plasma membrane permeabilization induced by EP changes the ADC, suggesting that DW-MRI constitutes a noninvasive and quick means of EP verification. In this study we performed in vivo EP in rat brains, followed by DW-MRI using a clinical MRI scanner. We found a pulse amplitude–dependent increase in the ADC following EP, indicating that (1) DW-MRI is sensitive to the EP-induced changes and (2) the observed changes in ADC are indeed due to the applied electric field.Keywords
This publication has 32 references indexed in Scilit:
- Optimizing clinical performance and geometrical robustness of a new electrode device for intracranial tumor electroporationBioelectrochemistry, 2011
- MR Imaging to Assess Immediate Response to Irreversible Electroporation for Targeted Ablation of Liver Tissues: Preclinical Feasibility Studies in a Rodent ModelRadiology, 2010
- Towards treatment planning and treatment of deep-seated solid tumors by electrochemotherapyBioMedical Engineering OnLine, 2010
- In vivoelectrical conductivity measurements during and after tumor electroporation: conductivity changes reflect the treatment outcomePhysics in Medicine & Biology, 2009
- Visualization of in vivo electroporation-mediated transgene expression in experimental tumors by optical and magnetic resonance imagingGene Therapy, 2009
- Physiological Effects of High- and Low-Voltage Pulse Combinations for Gene Electrotransfer in MuscleHuman Gene Therapy, 2008
- Estimation of cell membrane permeability of the rat brain using diffusion magnetic resonance imagingJournal of Applied Physics, 2008
- Diffusion-Weighted MRI in the Body: Applications and Challenges in OncologyAmerican Journal of Roentgenology, 2007
- Sequential Finite Element Model of Tissue ElectropermeabilizationIEEE Transactions on Biomedical Engineering, 2005
- Kinetics of pore resealing in cell membranes after electroporationBioelectrochemistry and Bioenergetics, 1991