Measurement of spinal range of motion in healthy individuals using an electromagnetic tracking device
Authors:
- 1 February 2008
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 8 (2) , 135-142
Abstract
Object: The authors measured the range of motion (ROM) of the spine in healthy individuals by using an electromagnetic tracking device to evaluate the functional performance of the spine. Methods: The authors used the Flock of Birds electromagnetic tracking device with 4 receiver units attached to C-7, T-12, S-1, and the midthigh region. Forward/backward bending, bilateral side bending, and axial rotation of the trunk were performed in 18 healthy individuals. Results: The average ROM was calculated after 3 consecutive measurements. The thoracic spine generated the greatest angle in axial rotation and smallest angle in backward bending. The lumbar spine generated the greatest angle in forward bending and smallest angle in axial rotation. The hip joints generated the greatest angle in forward bending and smallest angle in backward bending. Additionally, 40% of forward-bending motion occurred in the lumbar spine and 40% occurred in the hip joints. Approximately 60% of backward bending occurred in the lumbar spine; 60% of axial rotation occurred in the thoracic spine; and 45% of side bending occurred in the thoracic spine. Conclusions: The Flock of Birds electromagnetic tracking device cannot only measure the ROM of spine but also easily differentiate the 6-degree contributions by different segments.Keywords
This publication has 30 references indexed in Scilit:
- On the use of bone and skin markers in kinematics researchHuman Movement Science, 1996
- Determination of the proximity tolerance for measurement of surface contact areas using a magnetic tracking deviceJournal of Biomechanics, 1996
- Electromyographic analysis of four techniques for isometric trunk muscle exercisesArchives of Physical Medicine and Rehabilitation, 1995
- Kinematics of the Lumbar Spine Following Pedicle Screw Plate FixationSpine, 1993
- Influence of short hamstring muscles on the pelvis and lumbar spine in standing and during the toe-touch testClinical Biomechanics, 1992
- Clinical Validation of Functional Flexion-Extension Roentgenograms of the Lumbar SpineSpine, 1991
- Repeatability of Four Clinical Methods for Assessment of Lumbar Spinal MotionSpine, 1988
- Use of Noninvasive Techniques for Quantification of Spinal Range-of-Motion in Normal Subjects and Chronic Low-Back Dysfunction PatientsSpine, 1984
- Axial Rotation and Lateral Bending in the Normal Lumbar Spine Measured by Three-Dimensional RadiographySpine, 1984
- Three-Dimensional X-ray Analysis of Normal Movement in the Lumbar SpineSpine, 1984