The Effects of Sympathectomy on Finger Photoplethysmography and Temperature Measurements in Healthy Subjects
Authors:
- Pekka TalkePTPekka Talke
- Amir SnapirASAmir Snapir
- Matti HuikuMHMatti Huiku
- 1 July 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 113 (1) , 78-83
Abstract
Photoplethysmography uses light transmission to measure changes in tissue volume. The resulting photoplethysmogram is composed of AC and DC components. Limited data are available on the effects of vasodilation on the AC and the DC components of the photoplethysmograph signal. The aims of our study were (1) to investigate the effects of sympathectomy on different components of the photoplethysmogram, and (2) to compare sympathectomy-induced changes in the photoplethysmogram with changes in peripheral temperature. In 10 healthy subjects, sympathectomy-induced peripheral vasodilation was achieved using an axillary brachial plexus block. The nonblocked arm served as control. We obtained measurements of bilateral continuous measurements of finger blood volume (by photoplethysmography) and finger temperature. We separated the finger photoplethysmogram into its AC and DC components. In addition, we calculated the ratio of AC to DC (AC/DC). All data were recorded until 30 minutes after the end of brachial plexus block. Repeated-measures analysis of variance followed by the Dunnett post hoc test determined the effect of brachial plexus block on the finger photoplethysmogram and finger temperature. The DC component of the finger photoplethysmogram decreased (vasodilation) significantly (P < 0.0001) after brachial plexus block in the blocked arm starting 2.7 minutes after the block. Average decrease in DC values was -51% ± 19% (95% confidence interval: -61% to -42%) at 30 minutes after the block. None of the other photoplethysmogram components changed significantly from preblock baseline values. On average, the finger temperature increased significantly (P < 0.0001) starting 5.7 minutes after brachial plexus block in the blocked arm. Average increase in temperature was 7.1°C ± 3.8°C (95% confidence interval: 5.1°C-9.0°C) 30 minutes after the block. The DC component of the photoplethysmogram had the highest sensitivity and specificity to predict a successful block. This study characterizes sympathectomy-induced changes in the AC and DC components of the finger photoplethysmogram. In this experimental model, we found the DC component to be most sensitive in detecting peripheral vasodilation.Keywords
This publication has 11 references indexed in Scilit:
- Pulse oximeter perfusion index as an early indicator of sympathectomy after epidural anesthesiaActa Anaesthesiologica Scandinavica, 2009
- The Efficacy of Skin Temperature for Block Assessment After Infraclavicular Brachial Plexus BlockAnesthesia & Analgesia, 2009
- Sympathectomy-mediated vasodilatation: a randomized concentration ranging study of epidural bupivacaineCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2009
- Effects of nitric oxide synthase inhibition on dexmedetomidine-induced vasoconstriction in healthy human volunteersBritish Journal of Anaesthesia, 2008
- Uniform Distribution of Skin-Temperature Increase After Different Regional-Anesthesia Techniques of the Lower ExtremityRegional Anesthesia & Pain Medicine, 2007
- Uniform Distribution of Skin-Temperature Increase After Different Regional-Anesthesia Techniques of the Lower ExtremityRegional Anesthesia & Pain Medicine, 2007
- Peripheral Flow Index Is a Reliable and Early Indicator of Regional Block SuccessAnesthesia & Analgesia, 2006
- Skin Temperature During Regional Anesthesia of the Lower ExtremityAnesthesia & Analgesia, 2006
- Thermographic Temperature Measurement Compared with Pinprick and Cold Sensation in Predicting the Effectiveness of Regional BlocksAnesthesia & Analgesia, 2006
- Alpha-2B adrenoceptor polymorphism and peripheral vasoconstrictionPharmacogenetics and Genomics, 2005