Level of sensory block after spinal anesthesia as a predictor of hypotension in parturient
Authors:
Open Access
- 1 June 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 96 (25) , e7184
Abstract
When the sensory block level (SBL) is ≥T5 or T4, a high incidence of hypotension occurs in parturients after spinal anesthesia. A rapidly ascending SBL is another risk factor for spinal anesthesia-induced hypotension. However, the relationship between the ascension rate of the SBL and spinal anesthesia-induced hypotension remains unclear. After placement in the left lateral position, combined epidural–spinal anesthesia was performed on 140 parturients undergoing caesarean section using the following procedure: no volume preloading, injection site of L3–4 or L4–5, injection rate of 0.1 mL/sec, and administration of 10 mg of 0.5% hyperbaric bupivacaine. A receiver-operating characteristic curve was built to estimate the accuracy of the SBL ascension rate in detecting spinal anesthesia-induced hypotension. The mean time interval from spinal injection to placement in the supine position was 136 ± 10 seconds in all anesthesia procedures. The earliest and most complete records of the SBL started from the 3rd minute after spinal injection. The threshold spread rate corresponding to the highest accuracy for occurrence of hypotension was an SBL of ≥T8 at the 3rd minute after spinal injection, with 82% and 88% sensitivity and specificity, respectively. The ascension rate of an SBL of ≥T8 at the 3rd minute after spinal injection is as a predictor of hypotension in parturients.Keywords
This publication has 15 references indexed in Scilit:
- Gestation-Related Reduction in Lumbar Cerebrospinal Fluid Volume and Dural Sac Surface AreaAnesthesia & Analgesia, 2010
- Prospective study of hypotension after spinal anesthesia for cesarean section at Siriraj Hospital: incidence and risk factors, Part 2.2008
- Incidence and risk factors of hypotension and bradycardia after spinal anesthesia for cesarean section.2008
- ErrataCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2007
- Influence of injection rate of hyperbaric bupivacaine on spinal block in parturients: a randomized trialCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2007
- The Sitting Versus Right Lateral Position During Combined Spinal-Epidural Anesthesia for Cesarean Delivery: Block Characteristics and Severity of HypotensionAnesthesia & Analgesia, 2006
- The Effect of Posture and Baricity on the Spread of Intrathecal Bupivacaine for Elective Cesarean DeliveryAnesthesia & Analgesia, 2005
- Comparative effect of 6% hydroxyethyl starch (containing 1% dextrose) and lactated Ringer's solution for cesarean section under spinal anesthesiaJournal of Anesthesia, 2002
- Method of Ephedrine Administration and Nausea and Hypotension during Spinal Anesthesia for Cesarean SectionAnesthesiology, 1982
- Anesthesia for Cesarean SectionAnesthesiology, 1980