Electronic Implementation of a Novel Surveillance Paradigm for Ventilator-associated Events. Feasibility and Validation
- 15 April 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 189 (8) , 947-955
Abstract
Rationale: Accurate surveillance of ventilator-associated pneumonia (VAP) is hampered by subjective diagnostic criteria. A novel surveillance paradigm for ventilator-associated events (VAEs) was introduced. Objectives: To determine the validity of surveillance using the new VAE algorithm. Methods: Prospective cohort study in two Dutch academic medical centers (2011–2012). VAE surveillance was electronically implemented and included assessment of (infection-related) ventilator-associated conditions (VAC, IVAC) and VAP. Concordance with ongoing prospective VAP surveillance was assessed, along with clinical diagnoses underlying VAEs and associated mortality of all conditions. Consequences of minor differences in electronic VAE implementation were evaluated. Measurements and Main Results: The study included 2,080 patients with 2,296 admissions. Incidences of VAC, IVAC, VAE-VAP, and VAP according to prospective surveillance were 10.0, 4.2, 3.2, and 8.0 per 1000 ventilation days, respectively. The VAE algorithm detected at most 32% of the patients with VAP identified by prospective surveillance. VAC signals were most often caused by volume overload and infections, but not necessarily VAP. Subdistribution hazards for mortality were 3.9 (95% confidence interval, 2.9–5.3) for VAC, 2.5 (1.5–4.1) for IVAC, 2.0 (1.1–3.6) for VAE-VAP, and 7.2 (5.1–10.3) for VAP identified by prospective surveillance. In sensitivity analyses, mortality estimates varied considerably after minor differences in electronic algorithm implementation. Conclusions: Concordance between the novel VAE algorithm and VAP was poor. Incidence and associated mortality of VAE were susceptible to small differences in electronic implementation. More studies are needed to characterize the clinical entities underlying VAE and to ensure comparability of rates from different institutions.Keywords
This publication has 27 references indexed in Scilit:
- Toward Improved Surveillance: The Impact of Ventilator-Associated Complications on Length of Stay and Antibiotic Use in Patients in Intensive Care UnitsClinical Infectious Diseases, 2012
- The Dilemma of Assessment Bias in Infection Control ResearchClinical Infectious Diseases, 2012
- Multicenter Evaluation of a Novel Surveillance Paradigm for Complications of Mechanical VentilationPLOS ONE, 2011
- Ventilator-Associated Pneumonia: Preventing the InevitableClinical Infectious Diseases, 2011
- Interobserver variability in ventilator-associated pneumonia surveillanceAmerican Journal of Infection Control, 2010
- National Healthcare Safety Network (NHSN) report: Data summary for 2006 through 2008, issued December 2009American Journal of Infection Control, 2009
- An easy mathematical proof showed that time-dependent bias inevitably leads to biased effect estimationJournal of Clinical Epidemiology, 2008
- CDC/NHSN surveillance definition of health care–associated infection and criteria for specific types of infections in the acute care settingAmerican Journal of Infection Control, 2008
- Ventilator-Associated Pneumonia as a Quality Indicator for Patient Safety?Clinical Infectious Diseases, 2008
- A Proportional Hazards Model for the Subdistribution of a Competing RiskJournal of the American Statistical Association, 1999