Capillary isoelectric focusing of proteins utilizing poly(vinylpyrrolidone)‐ and plexiglas‐coated columns
- 13 January 2004
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 27 (1-2) , 124-128
Abstract
Fused‐silica capillaries chemically derivatized with silane/poly(vinylpyrrolidone) (PVP) or dynamically modified with plexiglas [poly(methyl methacrylate)] were prepared and evaluated with regard to column stability and separation performance for capillary isoelectric focusing of standard proteins. The PVP coating showed the better stability and was good for at least 100 runs while the plexiglas coating started to deteriorate after about 30 runs. The time spent for the plexiglas coating is about 40 minutes while the PVP coating requires two days. The migration time reproducibility was better with the PVP capillary (RSD 0.7–1.6%, n = 5) compared to the plexiglas‐coated column (RSD 1.2–2.9%, n = 5) while peak area and height varied over a similar interval (RSD 2–28.1% area; 0.9–22.7% height, n = 5). The two most consistent proteins in this evaluation, viz. myoglobin A and carbonic anhydrase II, showed linear dynamic ranges between 5–150 and 5–50 μg/mL, and limits of detections at 2 and 1 μg/mL, respectively, employing UV detection at 280 nm.Keywords
This publication has 18 references indexed in Scilit:
- The state of the art of dynamic coatingsElectrophoresis, 2001
- Polymer wall coatings for capillary electrophoresisElectrophoresis, 2001
- Room-Temperature Imprinting Method for Plastic Microchannel FabricationAnalytical Chemistry, 2000
- Protein adsorption to the bare silica wall in capillary electrophoresisJournal of Chromatography A, 2000
- High-resolution capillary isoelectric focusing of proteins using highly hydrophilic-substituted cellulose-coated capillariesJournal of Microcolumn Separations, 2000
- Microfabricated isoelectric focusing device for direct electrospray ionization-mass spectrometryElectrophoresis, 1999
- Demonstration of isoelectric focusing on an etched quartz chip with UV absorption imaging detection†The Analyst, 1999
- Adaptation of Capillary Isoelectric Focusing to Microchannels on a Glass ChipAnalytical Chemistry, 1998
- Capillary Isoelectric Focusing of Physiologically Derived Proteins with On-Line Desalting of Isotonic Salt ConcentrationsAnalytical Chemistry, 1997
- Cross-Linked Polymer Coatings for Capillary Electrophoresis and Application to Analysis of Basic Proteins, Acidic Proteins, and Inorganic IonsAnalytical Chemistry, 1997