Dynamic Assessment of Masonry Towers Based on Terrestrial Radar Interferometer and Accelerometers
Open Access
Abstract
This paper discusses the performance of a terrestrial radar interferometer for the structural monitoring of ancient masonry towers. High-speed radar interferometry is an innovative and powerful remote sensing technique for the dynamic monitoring of large structures since it is contactless, non-destructive, and able to measure fast displacements on the order of tenths of millimeters. This methodology was tested on a masonry tower of great historical interest, the Saint Prospero bell tower (Northern Italy). To evaluate the quality of the results, data collected from the interferometer were compared and validated with those provided by two types of accelerometer-based measuring systems directly installed on the tower. Dynamic tests were conducted in operational conditions as well as during a bell concert. The first aimed at characterizing the dynamic behavior of the tower, while the second allowed to evaluate the bell swinging effects. Results showed a good agreement among the different measuring systems and demonstrated the potential of the radar interferometry for the dynamic monitoring of structures, with special focus on the need for an accurate design of the geometric aspects of the surveys.Keywords
Funding Information
- Università Degli Studi di Modena e Reggio Emilia (FAR2016)
This publication has 30 references indexed in Scilit:
- A literature review of next-generation smart sensing technology in structural health monitoringStructural Control and Health Monitoring, 2019
- Human-induced vibrations of a curved cable-stayed footbridgeJournal of Constructional Steel Research, 2018
- Ambient vibration-based finite element model updating of an earthquake-damaged masonry towerStructural Control and Health Monitoring, 2018
- Using Ground Radar Interferometry for Precise Determining of Deformation and Vertical Deflection of StructuresIOP Conference Series: Earth and Environmental Science, 2017
- Influence of model errors in optimal sensor placementJournal of Sound and Vibration, 2017
- Selected geometric aspects of planning and analysis of measurement results of tall building structures using interferometric radar.Geomatics and Environmental Engineering, 2014
- Topography Mapping With a Portable Real-Aperture Radar InterferometerIEEE Geoscience and Remote Sensing Letters, 2011
- Remote Survey of the Leaning Tower of Pisa by Interferometric SensingIEEE Geoscience and Remote Sensing Letters, 2009
- Ambient vibration testing of historic masonry towers for structural identification and damage assessmentConstruction and Building Materials, 2007
- Optimal sensor placement methodology for parametric identification of structural systemsJournal of Sound and Vibration, 2004