The hydrodynamic stability of parallel multi-branch pipes within dividing manifold systems is importance to the internal fluid distribution network. However, under elevated Reynolds number conditions, severe flow field non-uniformity is frequently exhibited by these systems, manifesting as anomalous reverse flow in the upstream branches. Utilizing a combination of dimensional analysis, computational fluid dynamics, and particle image velocimetry, the triggering mechanisms of branch reverse flow and associated passive control methods within radiator pipe networks are investigated in this study. The results indicate that elevated inlet momentum results in a deflection of the streamlines toward the outer wall at the T-junction, thereby inducing a localized flow starvation zone that blocks the upstream branch, even inducing reverse flow. To alleviate this instability, a passive flow control strategy utilizing a customized micro-structure is proposed. Through the modulation of local streamline curvature, localized flow starvation is effectively alleviated by this micro-structure, and the fluid is redirected toward the radial branches, thereby suppressing reverse flow. Furthermore, the flow-regulating performance is contingent upon the geometric proportions of the micro-structure. It is demonstrated that optimal global hydrodynamic efficiency is achieved when the length-to-thickness ratio approaches η = 3, while branch reverse flow is simultaneously suppressed. Under this optimal configuration, the volumetric flow rate in the target branch is enhanced by a factor of 12.
Funding Information
  • National Natural Science Foundation of China (52207180)