Laser-Assisted Capsulotomy Centration: A Prospective Trial Comparing Pupil Versus OCT-Based Scanned Capsule Centration
Authors:
- Tim SchultzTSTim Schultz
- Nikolaos TsiampalisNTNikolaos Tsiampalis
- H. Burkhard DickHDH. Burkhard Dick
- 1 February 2017
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 33 (2) , 74-78
Abstract
To investigate different capsulotomy centration methods for femtosecond laser-assisted cataract surgery. The overlap between intraocular lens (IOL) optic and lens capsule was measured with different centration methods and IOL types. This was a prospective randomized clinical trial. Patients with cataract scheduled for femtosecond laser-assisted cataract surgery were assigned to one of four treatment groups: optical coherence tomography (OCT)-based scanned capsule centration (SCC) and three-piece IOL (SCC with three-piece IOL); scanned capsule centration and plate-haptic IOL (SCC with plate-haptic IOL); pupil centration (PC) and three-piece IOL (PC with three-piece IOL); or PC and plate-haptic IOL (PC with plate-haptic IOL). At the end of surgery, the overlap between the IOL optic and capsular bag was measured. The results of 160 patients were evaluated (n = 40 in each group). There was no difference in age (P = .27), sex (P = .18), the number of treated left and right eyes (P = .64), or cataract grade (P = .06). With the new SCC method (capsulotomy diameter: 5 mm), a complete overlap was achieved in all cases in both SCC groups. The overlap was also complete in all cases with PC and plate-haptic IOLs. In the PC with three-piece IOL group, the overlap was incomplete in 3 eyes. The SCC method helps to achieve a 360° overlap in all eyes independent of the IOL type. A complete 360° overlap was achieved in all cases up to a calculated capsulotomy diameter of 5.1 mm with this new method. [J Refract Surg. 2017;33(2):74-78.].Keywords
This publication has 15 references indexed in Scilit:
- Femtosecond laser–assisted cataract surgery—current status and future directionsSurvey of Ophthalmology, 2016
- Comparison of visual recovery and refractive stability between femtosecond laser–assisted cataract surgery and standard phacoemulsification: Six-month follow-upJournal of Cataract & Refractive Surgery, 2015
- Histologic Evaluation of in vivo Femtosecond Laser–Generated Capsulotomies Reveals a Potential Cause for Radial Capsular TearsEuropean Journal of Ophthalmology, 2014
- Incidence of acute postoperative cystoid macular edema in clinical practiceJournal of Cataract & Refractive Surgery, 2012
- Comparison of IOL Power Calculation and Refractive Outcome After Laser Refractive Cataract Surgery With a Femtosecond Laser Versus Conventional PhacoemulsificationJournal of Refractive Surgery, 2012
- Intraocular Lens Tilt and Decentration Measured By Scheimpflug Camera Following Manual or Femtosecond Laser–created Continuous Circular CapsulotomyJournal of Refractive Surgery, 2012
- Is Topography-guided Ablation Profile Centered on the Corneal Vertex Better Than Wavefront-guided Ablation Profile Centered on the Entrance Pupil?Journal of Refractive Surgery, 2012
- Femtosecond laser capsulotomyJournal of Cataract & Refractive Surgery, 2011
- Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract SurgeryJournal of Refractive Surgery, 2009
- Capsulorhexis size and posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1996