Use of an inertial measurement unit to assess the effect of forelimb lameness on three-dimensional hoof orientation in horses at a walk and trot
Authors:
- Raoul F. ReiserRRRaoul F. Reiser
- Christie A. MahaffeyCMChristie A. Mahaffey
- Michael L. PetersonMPMichael L. Peterson
- C. Wayne McIlwraithCMC. Wayne McIlwraith
- Christopher E. KawcakCKChristopher E. Kawcak
- 1 September 2014
- journal article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 75 (9) , 800-808
Abstract
Objective—To determine intralimb orientation changes with an inertial measurement unit (IMU) in hooves of horses at a walk and trot after induction of weight-bearing single forelimb lameness and to determine whether hoof orientations are similar to baseline values following perineural anesthesia. Animals—6 clinically normal horses. Procedures—3-D hoof orientations were determined with an IMU mounted on the right forelimb hoof during baseline conditions, during 3 grades of lameness (induced by application of pressure to the sole), and after perineural anesthesia. Linear acceleration profiles were used to segment the stride into hoof breakover, stance, initial swing, terminal swing, and total swing phases. Intralimb data comparisons were made for each stride segment. A repeated-measures mixed-model ANOVA was used for data analysis. Results—Lameness resulted in significant changes in hoof orientation in all planes of rotation. A significant increase in external rotation and abduction and a significant decrease in sagittal plane rotation of the hoof were detected at hoof breakover during lameness conditions. For sagittal plane orientation data, the SDs determined following perineural anesthesia were higher than the SDs for baseline and lameness conditions. Conclusions and Clinical Relevance—Results of this study indicated the IMU could be used to detect 3-D hoof orientation changes following induction of mild lameness at a walk and trot. An increase in data variability for a sagittal orientation may be useful for assessment of local anesthesia for hooves. The IMU should be further evaluated for use in clinical evaluation of forelimb lameness in horses.Keywords
This publication has 33 references indexed in Scilit:
- Effect of forelimb lameness on hoof kinematics of horses at a walkAmerican Journal of Veterinary Research, 2013
- Effect of forelimb lameness on hoof kinematics of horses at a trotAmerican Journal of Veterinary Research, 2013
- Use of a wireless, inertial sensor‐based system to objectively evaluate flexion tests in the horseEquine Veterinary Journal, 2012
- Accuracy and Precision of Equine Gait Event Detection during Walking with Limb and Trunk Mounted Inertial SensorsSensors, 2012
- Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable SystemJournal of Biomechanical Engineering, 2012
- Accuracy and precision of hind limb foot contact timings of horses determined using a pelvis-mounted inertial measurement unitJournal of Biomechanics, 2012
- The static accuracy and calibration of inertial measurement units for 3D orientationComputer Methods in Biomechanics and Biomedical Engineering, 2008
- Use of gyroscopic sensors for objective evaluation of trimming and shoeing to alter time between heel and toe lift-off at end of the stance phase in horses walking and trotting on a treadmillAmerican Journal of Veterinary Research, 2005
- Effects of mild forelimb lameness on exercise performanceEquine Veterinary Journal, 2002
- Kinematics in horses at the trot before and after an induced forelimb supporting lamenessEquine Veterinary Journal, 1997