Radiation Safety Issues in Y-90 Microsphere Selective Hepatic Radioembolization Therapy: Possible Radiation Exposure from the Patients
- 25 August 2010
- journal article
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- Vol. 44 (4) , 252-260
Abstract
The purpose of this study was to estimate the possible external radiation dose to other individuals from patients treated with Y-90 resin microspheres for unresectable hepatocellular carcinoma. We designed the study prospectively to estimate the possible radiation dose to other individuals from patients who had been treated with Y-90 microspheres for unresectable hepatocellular carcinoma. We estimated the total effective dose equivalent (TEDE) using two methods: ‘theoretical’ TEDEs according to the administered activity and ‘measured’ TEDE based on the ‘measured’ ambient radiation exposure rate. We compared the results from each method to determine when we can release patients from confinement at the earliest time complying with the patient release criteria. A total of 20 administrations of Y-90 resin microspheres were done in 18 patients. The average administered activity was 1.2 ± 0.77 (0.28–2.97) GBq. The ‘theoretical’ TEDEs were in the range of 0.8–10 μSv. The ‘measured’ TEDEs were in the range of 2.31–185 μSv. The measured TEDEs tend to be higher than the theoretical TEDEs. The values of theoretical and measured TEDE were both far less than 1 mSv, the upper limit at which the licensee can release a patient without any written documents. The effective dose equivalent caused by the Y-90 microsphere administered patient is very low. It is safe in terms of radiation safety to the other individuals when Y-90 microsphere radioembolization therapy is done with dose less than 3 GBq. Because the measured TEDE tends to be higher than the theoretical TEDE, it is recommended to use ‘measured’ TEDE for determining patient release.Keywords
This publication has 17 references indexed in Scilit:
- Posttherapy Radiation Safety Considerations in Radiomicrosphere Treatment with 90Y-MicrospheresJournal of Nuclear Medicine, 2007
- A NEW PROPOSAL FOR MONITORING PATIENTS IN NUCLEAR MEDICINEHealth Physics, 2006
- Radioembolization with Yttrium-90 Microspheres: A State-of-the-Art Brachytherapy Treatment for Primary and Secondary Liver MalignanciesJournal of Vascular and Interventional Radiology, 2006
- Calculating the absorbed dose from radioactive patients: the line-source versus point-source model.2002
- Yttrium-90 Microspheres: Radiation Therapy for Unresectable Liver CancerJournal of Vascular and Interventional Radiology, 2002
- Radioimmunotherapy for Non-Hodgkin's Lymphoma With Yttrium 90 Ibritumomab TiuxetanClinical Journal of Oncology Nursing, 2002
- Administration guidelines for radioimmunotherapy of non-Hodgkin's lymphoma with (90)Y-labeled anti-CD20 monoclonal antibody.2002
- Bremsstrahlung radiation exposure from pure beta-ray emitters.1999
- Revised Nuclear Regulatory Commission regulations for release of patients administered radioactive materials: outpatient iodine-131 anti-B1 therapy.1998
- Nonmyeloablative iodine-131 anti-B1 radioimmunotherapy as outpatient therapy.1998