Parallel and partial Fourier imaging with prospective motion correction
Open Access
- 9 April 2012
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (2) , 421-433
Abstract
Subject motion during scan is a major source of artifacts in MR examinations. Prospective motion correction is a promising technique that tracks subject motion and adjusts the imaging volume in real time; however, additional retrospective correction may be necessary to achieve robust image quality and compatibility with other imaging options. Real‐time realignment of the imaging volume by prospective motion correction changes the coil sensitivity weighting and the field inhomogeneity relative to the imaging volume. This can pose image reconstruction problems with parallel imaging and partial Fourier imaging, which rely on coil sensitivity and image phase information, respectively. This work presents a practical method for reconstructing images acquired using prospective motion correction with parallel imaging and/or partial Fourier imaging. Our proposed approach is data driven and noniterative; data are binned into several position bins based on motion measurements made during the prospective motion correction acquisition and the data in each bin are processed through intrabin operations such as parallel imaging reconstruction (in case of undersampling), phase correction, and coil combination before combination of the position bins. We demonstrate the effectiveness of our technique through simulation studies and in vivo experiments using a prospectively motion‐corrected three‐dimensional fast spin echo sequence. Magn Reson Med, 2013.Keywords
This publication has 27 references indexed in Scilit:
- Prospective motion correction for magnetic resonance spectroscopy using single camera retro‐grate reflector optical trackingJournal of Magnetic Resonance Imaging, 2011
- PROMO: Real‐time prospective motion correction in MRI using image‐based trackingMagnetic Resonance in Medicine, 2009
- Diffusion‐weighted imaging of the liver: Comparison of navigator triggered and breathhold acquisitionsJournal of Magnetic Resonance Imaging, 2009
- Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking systemNeuroImage, 2006
- SMASH, SENSE, PILS, GRAPPATopics in Magnetic Resonance Imaging, 2004
- Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithmEuropean Radiology, 2003
- Reconstruction after rotational motionMagnetic Resonance in Medicine, 2002
- Detection and elimination of motion artifacts by regeneration of k‐spaceMagnetic Resonance in Medicine, 2002
- Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRIMagnetic Resonance Materials in Physics, Biology and Medicine, 2002
- Accelerated Cardiac Imaging Using the SMASH TechniqueJournal of Cardiovascular Magnetic Resonance, 1999