Computer-aided Detection with Screening Mammography in a University Hospital Setting
Authors:
- Robyn L. BirdwellRBRobyn L. Birdwell
- Parul BandodkarPBParul Bandodkar
- Debra M. IkedaDIDebra M. Ikeda
- 1 August 2005
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 236 (2) , 451-457
Abstract
To prospectively assess the effect of computer-aided detection (CAD) on screening mammogram interpretation in an academic medical center to determine if the outcome is different than that previously reported for community practices. Institutional review board approval was granted, and informed consent was waived. During a 19-month period, 8682 women (median age, 54 years; range, 33-95 years) underwent screening mammography. Each mammogram was interpreted by one of seven radiologists, followed by immediate re-evaluation of the mammogram with CAD information. Each recalled case was classified as follows: radiologist perceived the finding and CAD marked it, radiologist perceived the finding and CAD did not mark it, or CAD prompted the radiologist to perceive the finding and recall the patient. Lesion type was also recorded. Recalled patients were tracked to determine the effect of CAD on recall and biopsy recommendation rates, positive predictive value (PPV) of biopsy, and cancer detection rate. A 95% confidence interval was calculated for cancer detection rate. Pathologic examination was performed for all cancers. Of 8682 patients, 863 (9.9%) with 960 findings were recalled for further work-up (Breast Imaging Reporting and Data System category 0). After further diagnostic imaging, it was recommended that biopsy or aspiration be performed for 181 of 960 findings (19%); 165 interventions were confirmed to have been performed. Twenty-nine cancers were found in this group, with a PPV for biopsy of 18% (29 of 165 findings) and a cancer detection rate of 3.3 per 1000 screening mammograms (29 of 8682 patients). CAD-prompted recalls contributed 8% (73 of 960 findings) of total recalled findings and 7% (two of 29 lesions) of cancers detected. Of 29 cancers (59%), 17 manifested as masses and 12 (41%) were microcalcifications. Ten (34%) cancers were ductal carcinoma in situ, and the remaining cancers had an invasive component. Both cancers found with CAD manifested as masses, and both were invasive ductal carcinoma. Prospective clinical use of CAD in a university hospital setting resulted in a 7.4% increase (from 27 to 29) in cancers detected. Both cancers were nonpalpable masses.Keywords
This publication has 13 references indexed in Scilit:
- Re: Changes in Breast Cancer Detection and Mammography Recall Rates After the Introduction of a Computer-Aided Detection SystemJNCI: Journal of the National Cancer Institute, 2004
- Changes in Breast Cancer Detection and Mammography Recall Rates After the Introduction of a Computer-Aided Detection SystemJNCI: Journal of the National Cancer Institute, 2004
- Apophyseal Joint and Intervertebral Disk Injuries Caused by Hyperflexion and HyperextensionRadiology, 2002
- Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast CenterRadiology, 2001
- Providing Professional Mammography Services: Financial AnalysisRadiology, 2001
- Potential Contribution of Computer-aided Detection to the Sensitivity of Screening MammographyRadiology, 2000
- Effect of human variability on independent double reading in screening mammographyAcademic Radiology, 1996
- Comparison of single reading with double reading of mammograms, and change in effectiveness with experienceBritish Journal of Radiology, 1995
- Benefit of independent double reading in a population-based mammography screening program.Radiology, 1994
- Previous mammograms in patients with impalpable breast carcinoma: retrospective vs blinded interpretation. 1993 ARRS President's Award.American Journal of Roentgenology, 1993