Can changes in implant macrogeometry accelerate the osseointegration process?: An in vivo experimental biomechanical and histological evaluations
Open Access
- 14 May 2020
- journal article
- retracted article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (5) , e0233304
Abstract
The propose was to compare this new implant macrogeometry with a control implant with a conventional macrogeometry. Eighty-six conical implants were divided in two groups (n = 43 per group): group control (group CON) that were used conical implants with a conventional macrogeometry and, group test (group TEST) that were used implants with the new macrogeometry. The new implant macrogeometry show several circular healing cambers between the threads, distributed in the implant body. Three implants of each group were used to scanning electronic microscopy (SEM) analysis and, other eighty samples (n = 40 per group) were inserted the tibia of ten rabbit (n = 2 per tibia), determined by randomization. The animals were sacrificed (n = 5 per time) at 3-weeks (Time 1) and at 4-weeks after the implantations (Time 2). The biomechanical evaluation proposed was the measurement of the implant stability quotient (ISQ) and the removal torque values (RTv). The microscopical analysis was a histomorphometric measurement of the bone to implant contact (%BIC) and the SEM evaluation of the bone adhered on the removed implants. The results showed that the implants of the group TEST produced a significant enhancement in the osseointegration in comparison with the group CON. The ISQ and RTv tests showed superior values for the group TEST in the both measured times (3- and 4-weeks), with significant differences (p < 0.05). More residual bone in quantity and quality was observed in the samples of the group TEST on the surface of the removed implants. Moreover, the %BIC demonstrated an important increasing for the group TEST in both times, with statistical differences (in Time 1 p = 0.0103 and in Time 2 p < 0.0003). Then, we can conclude that the alterations in the implant macrogeometry promote several benefits on the osseointegration process.Keywords
Funding Information
- Biotecnos
This publication has 44 references indexed in Scilit:
- Implant Stability and Bone Remodeling after 3 and 13 Days of Implantation with an Initial Static StrainClinical Implant Dentistry and Related Research, 2012
- Effect of Drilling Dimension on Implant Placement Torque and Early Osseointegration Stages: An Experimental Study in DogsJournal of Oral and Maxillofacial Surgery, 2012
- The effect of different implant macrogeometries and surface treatment in early biomechanical fixation: An experimental study in dogsJournal of the Mechanical Behavior of Biomedical Materials, 2011
- The Effects of Superficial Roughness and Design on the Primary Stability of Dental ImplantsClinical Implant Dentistry and Related Research, 2009
- Implant Compression Necrosis: Current Understanding and Case ReportJournal of Periodontology, 2009
- Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory studyClinical Oral Implants Research, 2009
- Osteocyte Density in the Peri‐Implant Bone of Immediately Loaded and Submerged Dental ImplantsJournal of Periodontology, 2009
- A study of the bone healing kinetics of plateau versus screw root design titanium dental implantsClinical Oral Implants Research, 2009
- Thoughts on limitations of animal modelsParkinsonism & Related Disorders, 2008
- A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: Preliminary reportClinical Oral Implants Research, 1997