The z‐sbDBA, a new concept for a dynamic sheet‐based fluence field modulator in x‐ray CT
Open Access
- 5 August 2020
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 47 (10) , 4827-4837
Abstract
Purpose: We present a new concept for dynamic fluence field modulation (FFM) in x‐ray computed tomography (CT). The so‐called z‐aligned sheet‐based dynamic beam attenuator (z‐sbDBA) is developed to dynamically compensate variations in patient attenuation across the fan beam and the projection angle. The goal is to enhance image quality and to reduce patient radiation dose.Methods: The z‐sbDBA consists of an array of attenuation sheets aligned along the direction. In neutral position, the array is focused toward the focal spot. Tilting the z‐sbDBA defocuses the sheets, thus reducing the transmission for larger fan beam angles. The structure of the z‐sbDBA significantly differs from the previous sheet‐based dynamic beam attenuator (sbDBA) in two features: (a) The sheets of the z‐sbDBA are aligned parallel to the detector rows, and (b) the height of the sheets increases from the center toward larger fan beam angles. We built a motor actuated prototype of the z‐sbDBA integrated into a clinical CT scanner. In experiments, we investigated its feasibility for FFM. We compared the z‐sbDBA to common CT bowtie filters in terms of the spectral dependency of the transmission and possible image variance distribution in reconstructed phantom images. Additionally, the potential radiation dose saving using z‐sbDBA for region‐of‐interest (ROI) imaging was studied.Results: Our experimental results confirm that the z‐sbDBA can realize variable transmission profiles of the radiation fluence by only small tilts. Compared to the sbDBA, the z‐sbDBA can mitigate some practical and mechanical issues. In comparison to bowtie filters, the spectral dependency is considerably reduced when using the z‐sbDBA. Likewise, more homogeneous image variance distributions can be attained in reconstructed phantom images. The z‐sbDBA allows controlling the spatial image variance distribution which makes it suitable for ROI imaging. Our comparison on ROI imaging reveals skin dose reductions of up to 35% at equal ROI image quality by using the z‐sbDBA.Conclusion: Our new concept for FFM in x‐ray CT, the z‐sbDBA, was experimentally validated on a clinical CT scanner. It facilitates dynamic FFM by realizing variable transmission profiles across the fan beam angle on a projection‐wise basis. This key feature allows for substantial improvements in image quality, a reduction in patient radiation dose, and additionally provides a technical solution for ROI imaging.Keywords
This publication has 42 references indexed in Scilit:
- Vision 20/20: Single photon counting x‐ray detectors in medical imagingMedical Physics, 2013
- The feasibility of a piecewise‐linear dynamic bowtie filterMedical Physics, 2013
- Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial resultsMedical Physics, 2013
- Design of a digital beam attenuation system for computed tomography: Part I. System design and simulation frameworkMedical Physics, 2013
- Fluence field optimization for noise and dose objectives in CTMedical Physics, 2011
- Dual-Source Dual-Energy CT With Additional Tin Filtration: Dose and Image Quality Evaluation in Phantoms and In VivoAmerican Journal of Roentgenology, 2010
- Strategies for Reducing Radiation Dose in CTRadiologic Clinics of North America, 2009
- The influence of bowtie filtration on cone‐beam CT image qualityMedical Physics, 2008
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Computerized transverse axial scanning (tomography): Part 1. Description of systemBritish Journal of Radiology, 1973