Zn–Mg–WC Nanocomposites for Bioresorbable Cardiovascular Stents: Microstructure, Mechanical Properties, Fatigue, Shelf Life, and Corrosion
- 29 December 2021
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 8 (1) , 328-339
Abstract
Zinc (Zn) and Zn alloys have been studied as potential materials for bioresorbable stents (BRSs) in the last decade due to their favorable biodegradability and biocompatibility. However, most Zn alloys lack the necessary combination of strength, ductility, fatigue resistance, corrosion rate (CR), and thermal stability needed for such applications. In this study, nanoparticles made of tungsten carbide (WC) were successfully incorporated into Zn alloyed with 0.5 wt % magnesium (Mg) and evaluated for their suitability for BRS applications. Specifically, the resulting Zn–0.5Mg–WC nanocomposite’s microstructure, mechanical properties, in vitro CR, and thermal stability were evaluated. The Zn–0.5Mg–WC nanocomposite had excellent mechanical strength [ultimate tensile strength (UTS) > 250 MPa], elongation to failure (>30%), and a suitable in vitro CR (∼0.02 mm/y) for this clinical application. Moreover, the Zn–0.5Mg–WC nanocomposite survived 10 million cycles of tensile loading (stress ratio, R = 0.053) when the maximum stress was 80% of the yield stress. Its ductility was also retained during a 90-day thermal stability study, indicating an excellent shelf life. Stent prototypes were fabricated using this composition and were successfully deployed during bench testing without fracture. These results show that the Zn–0.5Mg–WC nanocomposite is a promising material for BRS applications. In vivo studies are underway to validate both biocompatibility, stent function, and degradation.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01 HL143465)
This publication has 61 references indexed in Scilit:
- Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable StentsAdvanced Materials, 2013
- Palliative stent implantation for coarctation in neonates and young infantsAnnals of Pediatric Cardiology, 2012
- Morphology and properties of hot dip Zn–Mg and Zn–Mg–Al alloy coatings on steel sheetSurface and Coatings Technology, 2010
- Tungsten carbide cobalt nanoparticles exert hypoxia-like effects on the gene expression level in human keratinocytesBMC Genomics, 2010
- Toxicity of Tungsten Carbide and Cobalt-Doped Tungsten Carbide Nanoparticles in Mammalian Cells in VitroEnvironmental Health Perspectives, 2009
- Comparative toxicity of 24 manufactured nanoparticles in human alveolar epithelial and macrophage cell linesParticle and Fibre Toxicology, 2009
- Analysis of the transient expansion behavior and design optimization of coronary stents by finite element methodJournal of Biomechanics, 2006
- On the temperature dependence of the fatigue and damage behaviour of a particulate-reinforced metal-matrix compositeMaterials Science and Engineering: A, 2001
- Mode I fatigue cracking in a fiber reinforced metal matrix compositeActa Metallurgica et Materialia, 1993
- The phase equilibrium diagram for the KCl-NaCl systemMaterials Research Bulletin, 1967