Double‐bend needle modification for transthyrohyoid vocal fold injection
Authors:
- Jennifer AndrusJAJennifer Andrus
- Ramon FrancoRFRamon Franco
Open Access
- 11 October 2011
- journal article
- research article
- Published by Wiley in The Laryngoscope
- Vol. 122 (4) , 865-867
Abstract
Our objective was to describe an injection needle modification for awake in-office vocal fold injections through a percutaneous transthyrohyoid approach. Two separate 45° angle bends are created at the hub and 1 cm from the needle tip of a 25-gauge, 1.5-inch needle. After adequate endolaryngeal anesthesia, the needle is passed via the thyrohyoid membrane into the airway. The needle tip is at a 90° angle to the syringe, providing access to the entire vocal fold surface, regardless of chin position or thyroid cartilage angulation. The bend at 1 cm also serves as a marker to measure the depth of the needle within the soft tissue. The double-bend needle modification allows for complete access to the entire length of the true vocal fold in one pass as well as a marker to measure depth of the needle in the tissue. Limitations may include bleeding from the injection site, insufficient needle length in patients with a long anterior-posterior dimension of the larynx, and potential difficulty passing a needle through a calcified thyrohyoid membrane. Laryngoscope, 2012Keywords
This publication has 7 references indexed in Scilit:
- Accessing the vocal folds by transcutaneous injectionClinical Anatomy, 2010
- Voice Outcomes After Endoscopic Injection Laryngoplasty with Hyaluronic luronic Acid Stabilized GelThe Laryngoscope, 2010
- Thyrohyoid vocal fold augmentation with calcium hydroxyapatiteOtolaryngology–Head and Neck Surgery, 2008
- The thyrohyoid approach to in-office injection augmentation of the vocal foldCurrent Opinion in Otolaryngology & Head and Neck Surgery, 2007
- Thyrohyoid Approach for Vocal Fold AugmentationAnnals of Otology, Rhinology & Laryngology, 2006
- Thyrohyoid Approach to Cidofovir Injection: A Case StudyJournal of Voice, 2005
- Intracordal Injection of Teflon® in the Treatment of 135 Patients with DysphoniaAnnals of Otology, Rhinology & Laryngology, 1973