Characterizing the arrhythmogenic substrate in personalized models of atrial fibrillation: sensitivity to mesh resolution and pacing protocol in AF models
Open Access
- 1 March 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 23 (Supplement) , i3-i11
Abstract
Aims: Computationally guided persistent atrial fibrillation (PsAF) ablation has emerged as an alternative to conventional treatment planning. To make this approach scalable, computational cost and the time required to conduct simulations must be minimized while maintaining predictive accuracy. Here, we assess the sensitivity of the process to finite-element mesh resolution. We also compare methods for pacing site distribution used to evaluate inducibility arrhythmia sustained by re-entrant drivers (RDs). Methods and results: Simulations were conducted in low- and high-resolution models (average edge lengths: 400/350 µm) reconstructed from PsAF patients’ late gadolinium enhancement magnetic resonance imaging scans. Pacing was simulated from 80 sites to assess RD inducibility. When pacing from the same site led to different outcomes in low-/high-resolution models, we characterized divergence dynamics by analysing dissimilarity index over time. Pacing site selection schemes prioritizing even spatial distribution and proximity to fibrotic tissue were evaluated. There were no RD sites observed in low-resolution models but not high-resolution models, or vice versa. Dissimilarity index analysis suggested that differences in simulation outcome arising from differences in discretization were the result of isolated conduction block incidents in one model but not the other; this never led to RD sites unique to one mesh resolution. Pacing site selection based on fibrosis proximity led to the best observed trade-off between number of stimulation locations and predictive accuracy. Conclusion: Simulations conducted in meshes with 400 µm average edge length and ∼40 pacing sites proximal to fibrosis are sufficient to reveal the most comprehensive possible list of RD sites, given feasibility constraints.Keywords
Funding Information
- National Institutes of Health (U01-HL141074)
- Leducq Foundation (16 CVD 02)
- Theo-Rossi di Montelera (TRM) foundation
This publication has 28 references indexed in Scilit:
- Sensitivity of reentrant driver localization to electrophysiological parameter variability in image-based computational models of persistent atrial fibrillation sustained by a fibrotic substrateChaos: An Interdisciplinary Journal of Nonlinear Science, 2017
- Towards personalized computational modelling of the fibrotic substrate for atrial arrhythmiaEP Europace, 2016
- Feasibility of using patient-specific models and the “minimum cut” algorithm to predict optimal ablation targets for left atrial flutterHeart Rhythm, 2016
- Patient-derived models link re-entrant driver localization in atrial fibrillation to fibrosis spatial patternCardiovascular Research, 2016
- The Clinical Profile and Pathophysiology of Atrial FibrillationCirculation Research, 2014
- Magnetic resonance image intensity ratio, a normalized measure to enable interpatient comparability of left atrial fibrosisHeart Rhythm, 2014
- Verification of cardiac tissue electrophysiology simulators using an N -version benchmarkPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2011
- Molecular determinants of cardiac fibroblast electrical function and therapeutic implications for atrial fibrillationCardiovascular Research, 2010
- Atrial Fibrosis: Mechanisms and Clinical Relevance in Atrial FibrillationJACC, 2008
- Cost of an emerging epidemic: an economic analysis of atrial fibrillation in the UKHeart, 2004