Determination of Patient Radiation Dose During Ureteroscopic Treatment of Urolithiasis Using a Validated Model
- 1 March 2012
- journal article
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 187 (3) , 920-924
Abstract
We measured organ specific radiation dose rates and determined effective dose rates during simulated ureteroscopy using a validated model. To calculate the effective dose, patients were exposed to ureteroscopic management of stones at our institution. A validated anthropomorphic male phantom was placed on a fluoroscopy table and underwent simulated ureteroscopy. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ sites in the phantom and used to measure organ specific radiation doses. These dose rates were multiplied by the appropriate tissue weighting factor and summed to calculate effective dose rates. Also, we retrospectively reviewed the charts of patients who underwent ureteroscopy at our institution. A total of 30 nonobese males with data on fluoroscopy time were included in analysis. The median effective dose was determined by multiplying median fluoroscopy time by the effective dose rate. The skin entrance was exposed to the highest absorbed dose rate, followed by the small intestine (mean ± SD 0.3286 ± 0.0054 and 0.1882 ± 0.0194 mGy per second, respectively). The mean effective dose rate was 0.024 ± 0.0019 mSv per second. Median fluoroscopy time was 46.95 seconds (range 12.9 to 298.8). The median effective dose was 1.13 mSv (range 0.31 to 7.17). The fluoroscopy used during ureteroscopy contributes to overall radiation exposure in patients with nephrolithiasis. Nonobese males are exposed to a median of 1.13 mSv during ureteroscopy, similar to that of abdominopelvic x-ray. More data are needed to determine clinical implications but urologists must be aware and decrease patient radiation during ureteroscopy.Keywords
This publication has 17 references indexed in Scilit:
- Flexible Ureterorenoscopy and Holmium Laser Lithotripsy for the Management of Renal Stone Burdens That Measure 2 to 3 cm: A Multi-Institutional ExperienceJournal of Endourology, 2010
- Fluoroscopic Organ and Tissue-Specific Radiation Exposure by Sex and Body Mass Index During UreteroscopyJournal of Endourology, 2010
- 1804 VARIATION IN SURGICAL MANAGEMENT OF URINARY LITHIASIS IN THE UNITED STATESJournal of Urology, 2010
- Radiation Exposure in the Acute and Short-Term Management of Urolithiasis at 2 Academic CentersJournal of Urology, 2009
- Effective Doses in Radiology and Diagnostic Nuclear Medicine: A CatalogRadiology, 2008
- Effective dose: how should it be applied to medical exposures?British Journal of Radiology, 2007
- Effective Dose Determination Using an Anthropomorphic Phantom and Metal Oxide Semiconductor Field Effect Transistor Technology for Clinical Adult Body Multidetector Array Computed Tomography ProtocolsJournal of Computer Assisted Tomography, 2007
- AbstractAnnals of the ICRP, 2007
- Studies of Mortality of Atomic Bomb Survivors. Report 13: Solid Cancer and Noncancer Disease Mortality: 1950–1997Radiation Research, 2003
- Radiation-Related Cancer Risks at Low Doses among Atomic Bomb SurvivorsRadiation Research, 2000