Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery?☆
Authors:
- Rosanna AccardoRARosanna Accardo
- Massimo Di MaioMassimo Di Maio
- Carmine LamannaCLCarmine Lamanna
- Giovanni Battista RossiGRGiovanni Battista Rossi
- Maria Caterina PaceMPMaria Caterina Pace
- Vincenzo RomanoVRVincenzo Romano
- Gaetano RoccoGRGaetano Rocco
- 1 October 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 40 (4) , 912-918
Abstract
Flexible bronchoscopy is recommended to confirm correct placement of double-lumen tubes used for thoracic anesthesia. However, there is still controversy over routine bronchoscopic confirmation of their position. This study aimed to verify the usefulness of flexible bronchoscopy for confirming the position of double-lumen tubes after blind intubation. During a 9-month period, consecutive patients undergoing elective oncologic thoracic surgery were prospectively enrolled in the study. All patients were intubated with a left disposable polyvinyl chloride double-lumen tube. Immediately after intubation, clinical verification was made by the anesthesiologist. Then, the endoscopist performed flexible bronchoscopy with a 2.8-mm diameter Olympus(®) video bronchoscope, and verified the position of the double-lumen tube, before positioning the patient. The double-lumen tube was in optimal position, if the bronchial cuff was immediately below the tracheal carina, and there was a clear view of the left subcarina, with unobstructed left upper and lower bronchi. Misplacement of the double-lumen tube was diagnosed when the tube had to be moved (in or out) for more than 0.5 cm to correct its position. Critical malposition meant a double-lumen tube dislocated in the trachea or in the right bronchi, requiring immediate re-intubation under bronchoscopic guidance. A total of 144 patients (44 women (42%) and 60 men (58%), with a mean age of 51 years (range 25-77 years)) were enrolled in the study. Surgical procedures included 37 right-sided and 31 left-sided thoracotomies, 22 video-assisted thoracoscopic surgeries (VATSs) (16 right-sided and six left-sided), one median sternotomy, six mediastinotomies, and seven miscellaneous procedures. In 66 (63%, 95% confidence interval 53.2-71.8%) cases, there was complete agreement between the anesthesiologist and the endoscopist. The latter diagnosed misplacement of the double-lumen tube in 33 (32%, 95% confidence interval 22.8-40.7%) patients and critical malposition in five (5%, 95% confidence interval 0.7-8.9%) cases. After blind intubation, 37% of double-lumen tubes required repositioning by means of flexible bronchoscopy, despite positive evaluation made by the anesthesiologist. Our data suggests that initial bronchoscopic assessment should be made with the patient still in the supine position, and confirms that flexible bronchoscopy is useful in verifying the correct position of double-lumen tubes or adjusting possible misplacements, before starting thoracic surgery.Keywords
This publication has 22 references indexed in Scilit:
- Fiberoptic bronchoscopy need not be a routine part of double-lumen tube placementCurrent Opinion in Anaesthesiology, 2004
- Double-lumen tube position should be confirmed by fiberoptic bronchoscopyCurrent Opinion in Anaesthesiology, 2004
- Placement of double lumen tubes–time to shed light on an old problemBritish Journal of Anaesthesia, 2000
- Role of Fiberoptic Bronchoscopy in Conjunction with the Use of Double-lumen Tubes for Thoracic AnesthesiaAnesthesiology, 1998
- Placement of left double-lumen endobronchial tubes with or without a styletCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1996
- Incidence of malposition of polyvinylchloride and red rubber left-sided double-lumen tubes and clinical sequelaeJournal of Cardiothoracic and Vascular Anesthesia, 1995
- A quality improvement study of the placement and complications of double-lumen endobronchial tubesJournal of Cardiothoracic and Vascular Anesthesia, 1993
- CONTINUOUS SPIROMETRY FOR DETECTION OF DOUBLE-LUMEN ENDOBRONCHIAL TUBE DISPLACEMENTBritish Journal of Anaesthesia, 1993
- Reliability of auscultation in positioning of double-lumen endobronchial tubesCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1992
- PLACEMENT OF DOUBLE-LUMEN ENDOBRONCHIAL TUBESBritish Journal of Anaesthesia, 1986