STABILITY INDICATING HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF MOMETASONE FUROATE AND FORMOTEROL FUMARATE IN COMBINED DOSAGE FORM

Authors:

Abstract
A simple, specific, accurate, and stability indicating reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of formoterol fumarate and mometasone furoate using a Enamal C18 column and a mobile phase composed of acetonitrile: 0.05 M orthophosphoric acid: methanol (60:30:10 v/v), pH 3. The retention times of formoterol fumarate and mometasone furoate found to be 1.68 min and 7.17 min, respectively. Linearity was established for of formotero