High-Temporal Resolution Dual-Energy Computed Tomography of the Heart Using a Novel Hybrid Image Reconstruction Algorithm
- 1 January 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 35 (1) , 119-125
Abstract
Objectives: Dual-energy computed tomography (DECT) has been proposed for the comprehensive assessment of coronary artery stenosis and myocardial perfusion yet traditionally required reducing the temporal resolution of cardiac studies. We evaluated a reconstruction algorithm that preserves high temporal resolution at cardiac DECT. Methods: Twelve consecutive patients (3 women; mean [SD] age, 64 [10] years) with an abnormal single photon emission CT result underwent invasive coronary angiography and cardiac DECT. Dual-energy CT studies were reconstructed using the standard algorithm with 165-millisecond temporal resolution and a hybrid algorithm providing 83-millisecond temporal resolution. These studies were rated for coronary image quality and motion artifacts and compared with invasive coronary angiographic studies. Results: One hundred sixty-eight coronary artery segments (82%) were evaluated. The standard 165-millisecond reconstruction provided 95% diagnostic segments compared with 100% using the 83-millisecond hybrid reconstruction. Image quality was rated significantly (P < 0.05) better with hybrid reconstruction and had 91.4% sensitivity, 94.7% specificity, 82.1% positive predictive value, and 97.7% negative predictive value for detecting significant stenosis versus 85.7%, 93.2%, 76.9%, and 96.1% with standard reconstruction, respectively. Conclusions: Hybrid image reconstruction mitigates the former limitations in temporal resolution of cardiac DECT.Keywords
This publication has 30 references indexed in Scilit:
- Dual-Source versus 64-Section CT Coronary Angiography at Lower Heart Rates: Comparison of Accuracy and Radiation DoseRadiology, 2009
- Noninvasive Coronary Artery ImagingCirculation, 2008
- Randomized Comparison of 64-Slice Single- and Dual-Source Computed Tomography Coronary Angiography for the Detection of Coronary Artery DiseaseJACC: Cardiovascular Imaging, 2008
- Influence of Heart Rate on the Diagnostic Accuracy of Dual-Source Computed Tomography Coronary AngiographyJACC, 2007
- Quantification of Myocardial Perfusion Using Dynamic 64-Detector Computed TomographyInvestigative Radiology, 2007
- Artifacts in ECG-Synchronized MDCT Coronary AngiographyAmerican Journal of Roentgenology, 2007
- Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery diseaseEuropean Heart Journal, 2007
- ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 Appropriateness Criteria for Cardiac Computed Tomography and Cardiac Magnetic Resonance Imaging⁎⁎Developed in accordance with the principles and methodology outlined by ACCF: Patel MR, Spertus JA, Brindis RG, Hendel RC, Douglas PS, Peterson ED, Wolk MJ, Allen JM, Raskin IE. ACCF proposed method for evaluating the appropriateness of cardiovascular imaging. J Am Coll Cardiol 2005;46:1606–13.JACC, 2006
- Multidetector Computed Tomography Myocardial Perfusion Imaging During Adenosine StressJACC, 2006
- First performance evaluation of a dual-source CT (DSCT) systemEuropean Radiology, 2005