A Single Pipeline Embolization Device is Sufficient for Treatment of Intracranial Aneurysms
Open Access
- 30 April 2014
- journal article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 35 (8) , 1562-1566
Abstract
BACKGROUND AND PURPOSE: The Pipeline Embolization Device has emerged as an important treatment option for intracranial aneurysms. The number of devices needed to treat an aneurysm is uncertain and is the subject of vigorous debate. The purpose of this study was to compare rates of complications, aneurysm occlusion, and outcome in patients treated with a single-versus-multiple Pipeline Embolization Devices. MATERIAL AND METHODS: One hundred seventy-eight patients were treated with the Pipeline Embolization Device at our institution. Patients were divided into 2 groups: a single-device group (n = 126) and a multiple-device group (n = 52). RESULTS: There was no statistically significant difference between the 2 groups with respect to baseline characteristics except for age and aneurysm size (higher with multiple Pipeline Embolization Devices). Complications occurred more frequently with multiple (15%) versus a single device (5%, P = .03). In multivariate analysis, the use of multiple devices independently predicted complications. A similar proportion of patients achieved adequate aneurysm obliteration at follow-up in the single-device (84%) and the multiple-device groups (87%, P = .8). In multivariate analysis, age and follow-up time predicted obliteration. At follow-up, a significantly higher proportion of patients treated with a single device (97%) achieved a favorable outcome compared with those treated with multiple devices (89%, P = .03). In multivariate analysis, there was a strong trend for the use of a single device to predict favorable outcomes (P = .06). CONCLUSIONS: Treatment with a single Pipeline Embolization Device provides similar occlusion rates with less complications and better overall outcomes. These findings suggest that a single Pipeline Embolization Device is sufficient for treatment of most intracranial aneurysms.Keywords
This publication has 22 references indexed in Scilit:
- Extending the Indications of Flow Diversion to Small, Unruptured, Saccular Aneurysms of the Anterior CirculationStroke, 2014
- Current Status of Pipeline Embolization Device in the Treatment of Intracranial Aneurysms: A ReviewWorld Neurosurgery, 2013
- Endovascular Treatment of Middle Cerebral Artery Aneurysms with Flow Modification with the Use of the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2013
- Comparison of Flow Diversion and Coiling in Large Unruptured Intracranial Saccular AneurysmsStroke, 2013
- Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical TrialRadiology, 2013
- Treatment of Posterior Circulation Aneurysms With the Pipeline Embolization DeviceNeurosurgery, 2013
- Treatment of recurrent intracranial aneurysms with the Pipeline Embolization DeviceJournal of NeuroInterventional Surgery, 2013
- Intracranial Aneurysms: Midterm Outcome of Pipeline Embolization Device—A Prospective Study in 143 Patients with 178 AneurysmsRadiology, 2012
- Marked decrease in coil and stent utilization following introduction of flow diversion technologyJournal of NeuroInterventional Surgery, 2012
- Immediate and Midterm Results following Treatment of Unruptured Intracranial Aneurysms with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2011